ENGLISH
Symbols in these Instructions for Use
Important information for your safety is specially marked. It is
essential to comply with these instructions in order to avoid ac-
cidents and prevent damage to the machine:
WARNING:
This warns you of dangers to your health and indicates
possible injury risks.
CAUTION:
This refers to possible hazards to the machine or other
objects.
NOTE: This highlights tips and information.
Special Safety Instructions
Do not suck up liquids!
Do not suck up hot ashes or pointed or sharp objects!
Do not use the device in damp rooms!
Never use without the lter. Check that the lter is inserted
correctly!
Hair, clothing and body parts away from the vacuum nozzle
during use!
Keep the vacuum cleaner away from sources of heat like
radiators, ovens, etc.!
Overview of the Components
1 Vacuum hose
2 Dust bag lling display
3 Carrying handle
4 Cable-winding key
5 On/off switch and continuous power regulator
6 Cable
7 Accessory compartment
(groove and brush nozzle)
8 Dust bag compartment
9 Handle for opening
the dust bag compartment
10 Floor nozzle (with hook (not shown))
11 Groove and brush nozzle (Accessories)
12 Telescopic suction tube
13 Air Slide
Start-up
Insert the connection head of the suction hose into the hose
connector until it locks in place. To do so, please press the
buttons simultaneously. In order to release the hose again,
please press the buttons once more on the connection
head.
Keep the buttons pressed down and then pull out the hose.
Insert the vacuum tube into the handle if required.
Then assemble the oor nozzle and/or the accessories.
Accessory Compartment (7)
The accessories (crevice and brush nozzle) are located in the
accessory compartment next to the cable duct.
Telescope Vacuum Pipe
The height-adjustable vacuum pipe enables
individual alignment to your height. Unlock the
coupling by pressing the key in the direction of the
arrow. Slide the vacuum pipe to the desired length.
To lock the device, release the key until you hear
it lock in place.
Using the Appliance
1. Unwind the length of cable you require.
CAUTION:
Pull out the cable up to the maximum length indicated
with the yellow mark.
Never pull the cable out up to the red mark as the
cable winding can be damaged.
NOTE:
If the red mark is visible, pull in the cable with the help of
the cable winding button back to the yellow mark.
2. Insert the mains plug into a correctly installed 230 V, 50 Hz
power socket. Turn the device on by the on/off switch by
pressing down the button.
3. Set the “carpet/hard oor” switch, depending on the oor
covering.
4. Set the vacuum power with the vacuum power regulator
(Min to Max).
5. Vacuum at a steady speed. There is no need to exert pres-
sure.
NOTE:
Pay attention to the range that can be covered with the cable
length!
Vacuum power regulator (5)
Low vacuum power: For curtains and delicate fabrics.
Medium vacuum power: For long-pile velour carpets and textile
ooring.
High vacuum power: For sturdy rugs and oors.
Air Slide (13)
Open the air slide on the hose handle in order to
regulate the airow or to clear any particles sticking
to the nozzle.
Switching off and Winding up the Mains Lead
1. Turn the vacuum cleaner off by the on/off switch and remove
the plug from the socket.
2. Keep the plug in your hand.
3. Press the cable winding button and guide the cable. Hold
the cable to avoid wrapping.
Nozzle Attachment
Crevice and
jointed nozzle: For vacuuming upholstery, curtains and in
corners and crevices etc.
NOTE: „2-in-1“ nozzle:
When this is folded together it can be
used as a groove nozzle. If you would like
to use the brush nozzle, pull the brush
section in the direction of the arrow until it
locks in place.
Floor nozzle: To clean carpets or smooth surfaces.
Smooth oors: Press down the lever with
the brush symbol with your
foot. The brush is now vis-
ible.
Carpets: Press the lever n the oppo-
site direction. The brushes
are now retracted.
Releasing
the nozzles: Pull these off while turning slightly.
Maintenance
Dust bag replacement display (2)
Hold the hose up into air. If the dust bag change display lights
up, the bag is full. Please change it.
Changing the dust bag
Pull the plug out of the socket.
Open the lid of the dust bag compartment by the handle (9).
Then remove the dust bag by pulling it upwards.
Insert a new bag. Please ensure that the bag is located cor-
rectly in the guide mechanism. Press down the fastener with
the bag. The bag must be located completely in the dust bag
compartment. Close the cover so that it snaps into place.
Filter
Your appliance has two lters.
Motor protection filter (inlet filter):
The inlet lter is located in the dust bag compartment. The
lter is located vertically in the rear section of the dust housing.
Remove the lter by pulling upwards.
Cleaning the Filter Element
Clean the engine protection lter after 10 dust bag changes. If
necessary, the lter can also be washed in warm water without
any additives. Place it back into place only once it is completely
dry!
05-BS 1279.indd 25 17.08.2010 14:21:56 Uhr
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clatronic BS 1279 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clatronic BS 1279 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info