Floor nozzle
To clean carpets or smooth surfaces.
Smooth fl oors: Press down the lever with the
brush symbol with your foot.
The brush is now visible.
Carpets: Press the lever In the opposi-
te direction. The brushes are
now retracted.
Releasing the nozzles: Pull these off while turning
slightly.
Vacuum power regulator (3)
Low vacuum power: For curtains and delicate
fabrics
Medium vacuum power: For long-pile velour carpets
and textile fl ooring
High vacuum power: For sturdy rugs and fl oors
Telescopic Suction Tube (13)
As the length of the suction tube can be adjusted it can
be adapted to your own personal height. Unlock the
coupling by pressing the button (14) downwards.
Then move the telescopic suction tube to the desired
height. To x the suction tube in position, pull it until it is
heard to lock in place.
Cable winding device
Pull out the cable (1) up to the maximum length indicated
with the yellow mark. Never pull the cable out up to the
red mark as the cable winding can be damaged. Said
damages are not covered by the warranty.
Winding
Press the cable (5) winding button and guide the cable.
Hold the cable to avoid wrapping.
Air Slide
Open the air slide on the hose handle in order to regulate
the airfl ow or to clear any particles sticking to the nozzle.
Dust bag replacement display (8)
Hold the hose up into air. If the dust bag change display
lights up, the bag is full. Please change it.
Changing the dust bag
Pull the plug out of the socket.
Press the button (10) to open the lid of the dust bag
compartment (until its locks in place).
Pull the dust bag out of the holder.
Insert a new dust bag.
Close the cover so that it snaps into place.
Filter
Your appliance has two fi lters.
Motor protection fi lter (inlet fi lter)
The inlet fi lter is located in the dust bag compartment.
Press the button (10) to open the lid of the dust bag
compartment. The fi lter is located vertically in the rear
section of the dust housing. Remove the fi lter by pulling
upwards. Clean the engine protection fi lter after 10 dust
bag changes. If necessary, the fi lter can also be washed
in warm water without any additives. Place it back into
place only once it is completely dry!
Outlet fi lter
The appliance is also equipped with an outlet fi lter. This
lter is located in the dust bag space under the ventilation
grille. Open the dust bag compartment. Remove the fi lter
and clean as described above. Please reinsert the fi lter
correctly and then close the ventilation grille.
Coarse Dirt Filter
This collects the coarse dirt.
Empty the container (7.2) when the MAX. mark is
reached.
When suction power decreases!
Even if the MAX mark on the coarse dirt fi lter has not
yet been reached it is possible that the suction power
of your vacuum cleaner will decrease. You should
then also clean the container.
In order to do so, remove the container and the cover.
Note: The components can be removed or attached
by means of short twists in a clockwise or anticlo-
ckwise direction. Under the cover 7.1 there is an air
duct that also has to be cleaned.
Cleaning and storage
Cleaning
Pull the plug out of the socket before cleaning!
Clean the casing with a dry cloth.
Storage
Let the iron cool down completely.
Wind the cable completely.
Please place the machine in a vertical position and
insert the hook on the suction tube into the parking
assistance on the back.
Technical Data
Model: ................................................................. BS 1254
Power supply: ................................................230 V, 50 Hz
Power consumption:
P
nom.
:.................................................................1800 W
P
max.
:.................................................................2300 W
Protection class: ..............................................................ΙΙ
This device has been tested according to all relevant cur-
rent CE guidelines, such as electromagnetic compatibility
and low voltage directives, and has been constructed in
accordance with the latest safety regulations.
05-BS 1254 26 20.02.2006, 14:26:42 Uhr
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Clatronic bs 1254 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Clatronic bs 1254 in the language / languages: English, German, Dutch, French, Italian, Polish, Portuguese, Spanish, Norwegian as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info