28 29
13. All-Reset
• The watch may not display the time correctly if subjected to static electricity, magnets,
strong impact, or other adverse effects. When this happens, perform the All-Reset
procedure.
• Before performing the All-Reset procedure, be sure to charge the watch until the
charge indicator hand points to at least level 2 and the chronograph is in the reset
state.
[All-Reset Procedure]
1. When the second hand has reached
the 60-second position, pull out to
the crown to the time adjustment
position (second click).
2. Press buttons (A) and (C) at the
same time.
• The charge indicator hand moves
to level 3, and the watch
automatically performs reference
position alignment.
Button (A)
Chronograph second hand
Button
(C)
Second hand
Charge indicator
hand
Time adjustment
position
3. Return the crown to the normal position.
• The charge indicator hand performs a demonstration movement (pendulum
movement), and the second hand begins 1-second interval movement. The charge
indicator hand points to level 2 or 3.
• This completes the All-Reset procedure. Make the correct time and other settings using
the respective procedures before using the watch. If the All-Reset procedure cannot be
performed, send in your watch for repairs.