22 CHAPTER 1: INTRODUCING THE SWITCH 3300 XM, SM, TM, MM
The key topology rules are:
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
A 412m (1352ft) fiber run is allowed for connecting switch-to-switch,
or endstation-to-switch, using half-duplex 100BASE-FX.
A total network span of 325m (1066ft) is allowed in single-repeater
topologies (one hub stack per wiring closet with a fiber run to the
collapsed backbone). For example, a 225m (738ft) fiber link from a
repeater to a router or switch, plus a 100m (328ft) UTP link from a
repeater out to the endstations.
Configuration Rules
with Full Duplex
The Switch provides full duplex support for all its ports. Full duplex allows
packets to be transmitted and received simultaneously and, in effect,
doubles the potential throughput of a link.
With full duplex, the Ethernet topology rules are the same, but the Fast
Ethernet rules are:
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
A 2km (6562ft) fiber link is allowed for connecting switch-to-switch,
or endstation-to-switch.
1697ua.bk Page 22 Monday, December 3, 2001 11:31 AM
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cisco superstack switch 3300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cisco superstack switch 3300 in the language / languages: English as an attachment in your email.

The manual is 4,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info