Computer instructions for 99062
The enclosed training computer provides high convenience in training.
All values relevant to the training are displayed in a corresponding
window.
From the beginning of the training session onwards, the required time,
the current speed, the approximate energy consumption, the travelled
distance and the current pulse rate are displayed. All values are recorded
incrementally for zero upwards. If the training session is to last for a
particular period, a particular number of calories is to be consumed, a
particular distance travelled and a particular pulse rate not exceeded,
these values can be entered individually or as combinations.
The computer is switched on by briefl y pressing one of the buttons or
simply by beginning a training session. Select the desired function for
input by pressing the „F“ button. The function which can be changed is
displayed.
Each desired value can be entered by pressing the two arrow buttons.
The „E“ button stand for an increasing value starting from zero
and also for a decreasing value starting from the maximum value.
To start the computer, simply begin your training session. The computer
then begins to measure and display all values.
To stop the computer, simply end the training session. The computer
stops all measurements and holds the last achieved values. The last
reached values in the functions TIME, CALORIES, ODO and KM are
stored and training can proceed with these values when the training
session is resumed.
The computer switches off automatically approx. 4 minutes after the
training session has ended. All values reached by then are erased.
Displays:
1. „TMR“ time- display:
Usually, the currently required time is displayed in minutes and seconds.
A particular value can be specifi ed using the „E“ button. If a particular
time has been specifi ed, the remaining time is displayed. When
the specifi ed time has elapsed, this is indicated by an acoustic signal.
In this function, the last reached time is stored until the computer
switches off. (Maximum limit of the display is 99.59 minutes.)
2. „SPD“ speed- display:
The current speed is displayed n kilometres per hour. A particular value
cannot be specifi ed with the „E“ button. The last achieved value is not
stored in this function.
(Upper limit of the display is 99.9 km/h)
3. „CAL“ display:
The current amount of consumed calories is displayed. A particular
value can be specifi ed with the „E“ button. If a particular consumed
amount is specifi ed, the amount of calories remaining to be
consumed is displayed. When the specifi ed value is reached, this is
indicated by an acoustic signal.
In this function, the last reached time is stored until the computer
switches off. (Upper limit of the display is 9:999 calories)
4. „DST“ display:
The current value of the travelled kilometres is displayed. A particular
value can be specifi ed with the „E“ button. If a particular distance
is specifi ed, the distance remaining to be travelled is displayed. When
the specifi ed value is reached, this is indicated by an acoustic signal.
In this function, the last reached time is stored until the computer
switches off. (Upper limit of the display is 99,99 km)
5. „PULSE“ display:
The current pulse rate is displayed in beats per minute (bpm).
A particular value can not be specifi ed with the „E“ button.
(Upper limit of the display is 90- 220 pulse beats per minute)
6. „ODO“ TOTALDISTANCE - display:
The current status of the travelled kilometres of all previous training
sessions including current training session is displayed. A particular value
cannot be specifi ed. The values last attained by this function are stored.
(Limit of the display: 9.999 km.)
7. „SCAN“ function :
If this function is selected, the current values of all functions are displayed
successively in a constant sequence approx. every 5 seconds.
Buttons:
1. „E“ enter-key:
The specifi ed values of the individual functions can be entered in steps
by each pressing of these buttons. The desired function must fi rstly be
selected using the „F“ button.
After training has begun, the display counts down from the specifi ed
value to zero.
2. „F“ function-key:
Pressing this key once briefl y makes it possible to change from one
function to another, i.e. the respective functions can be selected for which
entries can be made using the „E“ key. The currently selected function is
indicated by an icon in the respective window.
Holding the key pressed (approx. 2 seconds) allows all last attained
values to be deleted. All values of all displays are then set to zero except
the Totaldistance „ODO“.
3. „L“ = Delete -key:
When this key is pressed briefl y, the values chosen with the „E“ key are
reset to zero.
English
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Christopeit CPS 6 - 99063 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Christopeit CPS 6 - 99063 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info