9.5. GLOSSARY
ϕ Phase shift of the phase-neutral voltage with respect to the phase-neutral current.
Inductive phase shift.
Capacitive phase shift.
° Degree.
% Percentage.
A Ampere (unit of current).
AC AC component (current or voltage).
Aggregation 9.2.
CF Crest factor of the current or voltage: ratio of the crest (peak) value of a signal to the RMS value.
cos ϕ Cosine of the phase shift of the phase-neutral voltage with respect to the phase-neutral current.
DC DC component (current or voltage).
Ep Active energy.
Eq Reactive energy.
Es Apparent energy.
f (Frequency) Number of complete periods of voltage or current per second.
Fundamental component: component at the fundamental frequency.
Harmonics In electrical systems, voltages and currents at multiples of the fundamental frequency.
Hz Hertz (unit of frequency).
I Symbol of the current.
I-CF Crest factor of the current.
I-THD Total harmonic distortion of the current.
IL RMS current (L = 1, 2 or 3)
IL-Hn Value or percentage of current of the nth harmonic (L = 1, 2 or 3).
L Phase of a polyphase electrical network.
MAX Maximum value.
Measurement method: Any measurement method associated with an individual measurement.
MIN Minimum value.
Nominal voltage: Nominal voltage of a network.
Order of a harmonic: ratio of the frequency of the harmonic to the fundamental frequency; a whole number.
P Active power.
PF Power Factor - ratio of the active power to the apparent power.
Phase Time relation between current and voltage in AC circuits.
Q Reactive power.
RMS Root Mean Square of the current or voltage. Square root of the mean of the squares of the instantaneous values

S Apparent power.
tan Φ Ratio of the reactive power to the active power.
THD Total Harmonic Distortion. This characterizes the proportion of harmonics of a signal with respect to the RMS
value of the fundamental component or the total RMS value without the DC component.
U Voltage between two phases.
U-CF Crest factor of the phase-phase voltage.
u2 Unbalance of the phase-neutral voltages.
UL-Hn Value or percentage of phase-phase voltage of the nth harmonic (L = 1, 2 or 3)
Unbalance of the voltages of a polyphase network: State in which the RMS voltages between conductors (fundamental com-
󰀨
Uxy-THD Total harmonic distortion of the voltage between two phases.
V Phase-neutral voltage or Volt (unit of voltage).
V-CF Crest factor of the voltage
V-THD Total harmonic distortion of the phase-neutral voltage.
VA Unit of apparent power (Volt x Ampere).
var Unit of reactive power.
varh Unit of reactive energy.
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chauvin Arnoux PEL105 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chauvin Arnoux PEL105 in the language / languages: English as an attachment in your email.

The manual is 11,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info