Frequency number of full voltage or current cycles in one second.
Fundamental component: component at the fundamental frequency.
Harmonics in electrical systems, voltages and currents at frequencies that are multiples of the fundamental frequency.
Hz Frequency of the network.
I Abbreviation for current.
I-CF Crest (peak) factor of current
I-THD Total harmonic distortion of current
Ix-Hh Current value or percentage for harmonic order n.
L Phase of a polyphased electrical power network.
MAX Maximum value.
Measurement method: Any measurement method associated with an individual measurement.
MIN Minimum value.
Nominal voltage: Reference voltage of a network.
Order of a harmonic: ratio of the frequency of the harmonic to the fundamental frequency; a whole number.
P Abbreviation for active power.
PF Power Factor: ratio of active power to apparent power.
Phase temporal relationship between current and voltage in alternating current circuits.
Q Abbreviation for reactive power.
RMS RMS (Root Mean Square) value of current or voltage. Square root of the mean of the squares of the instantaneous

S Abbreviation for apparent power.
tan Φ Ratio of reactive power to active power.
THD Total Harmonic Distortion. The total harmonic distortion describes the proportion of the harmonics of a signal with
respect to the RMS value of the fundamental or to the total RMS value without DC.
U Phase-to-phase voltage.
U-CF Phase-to-phase voltage crest factor
u2 Phase-to-neutral voltage unbalance.
Ux-Hn Phase-to-phase voltage (value or percentage) for harmonic order n.
Uxy-THD Total phase-to-phase voltage harmonic distortion
V 
V-CF Voltage crest (peak) factor
VA Apparent power unit (Volt-Ampere).
var Reactive power unit.
varh Reactive energy unit.
V-THD Total harmonic distortion of phase-to-neutral voltage.
Voltage unbalance in a polyphased electrical power network: State in which the RMS voltages between conductors (fundamental
󰀨
Vx-Hn Phase-to-neutral voltage (value or percentage) for harmonic order n.
W Active power unit (Watt).
Wh Active energy unit (Watt-hour).

Prex Symbol Multiplies by
milli m 10-3
kilo k 103
Mega M 106
Giga G 109
Tera T 1012
Peta P 1015
Exa E 1018
78


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chauvin Arnoux PEL103 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chauvin Arnoux PEL103 in the language / languages: English as an attachment in your email.

The manual is 9,98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Chauvin Arnoux PEL103

Chauvin Arnoux PEL103 Quick start guide - English, German - 52 pages

Chauvin Arnoux PEL103 User Manual - German - 70 pages

Chauvin Arnoux PEL103 Quick start guide - Dutch, French, Italian, Polish, Swedish, Spanish, Finnish - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info