OPERATING INSTRUCTIONS
CHIMNEY SWEEPING
Where the chimney previously served an open fire, it is possible
that the higher flue gas temperature from a stove may loosen soot
deposits with the consequent risk of flue blockage. It is therefore
recommended that the chimney be swept a second time within a
month of regular use after installation.
The chimney should be swept at least twice a year. Where the top
outlet or vertical rear flue connector is used it will generally be
possible to sweep the chimney through the appliance.
First remove the fuel retainer, throat plate and upper baffle (Skye 7
only). Then sweep the chimney ensuring that soot is removed from
all horizontal surfaces after sweeping.
In situations where it is not possible to sweep through the appliance
the installer will have provided alternative means, such as a soot
door. After sweeping the chimney the appliance flue outlet and the
flue pipe connecting the stove to the chimney must be cleaned with
a flue brush.
After clearing any soot from within the stove, replace upper baffle
(Skye 7), the throat plate (see Fig. 5) and the fuel retainer.
Different types of sweep’s brushes are available to suit different
flueways. For prefabricated insulated chimneys the manufacturers
instructions with regard to sweeping should be consulted.
TROUBLE SHOOTING
Fire Will Not Burn
Check that:
a) the air inlet is not obstructed in any way,
b) chimneys and flueways are clear,
c) a suitable fuel is being used,
d) there is an adequate air supply into the room,
e) an extractor fan is not fitted in the same room as the stove.
f) there is sufficient draw in the chimney. Once the chimney is warm
a draught reading of at least 1.25 mm (0.05 in.) water gauge (12Pa)
should be obtained.
Blackening of Door Glass
Differences in chimney draughts mean that the best settings of the
air controls will vary for different installations. A certain amount of
experimentation may be required, however the following points
should be noted and with a little care should enable the glass to be
kept clean in most situations:
a) Wet or unseasoned wood, or logs overhanging the front fence will
cause the glass to blacken.
b) The airwash relies on a supply of heated air to keep the glass clean,
therefore, when lighting the stove allow the firebed to become well
established before closing the air control. This may also be necessary
when re-fuelling the stove.
c) When re-fuelling keep the fuel as far back from the front fence as
possible, do not try to fit too much fuel into the firebox.
d) Do not completely close the air control.
It is always more difficult to keep the glass clean when running the
stove very slowly for long periods.
If blackening of the glass still occurs check that all flue connections
and the blanking plate are well sealed. It is also important that the
chimney draw is sufficient and that it is not affected by down-draught.
When the chimney is warm a draught reading of at least 1.25 mm
(0.05 in.) water gauge (12Pa) should be obtained. Some blackening
of the glass may occur below the level of the fuel retainer. This will
not obscure the view of the fire or affect its performance.
Fume Emission
Warning Note:
Properly installed and operated this appliance will not emit fumes.
Occasional fumes from de-ashing and re-fuelling may occur. Persistent
fume emission is potentially dangerous and must not be tolerated.
If fume emission does persist, then the following immediate actions
should be taken:
a) Open doors and windows to ventilate the room and then leave
the premises.
b) Let the fire out and safely dispose of the fuel from the appliance.
c) Check for flue or chimney blockage, and clean if required.
d) Do not attempt to re-light the fire until cause of fuming has been
identified, if necessary seek professional advice.
The most common cause of fume emission is flueway or chimney
blockage. For your own safety these must be kept clean.
Fire blazing out of control
Check that:
a) The door is tightly closed.
b) The air control slider is fully closed.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood Skye 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood Skye 5 in the language / languages: English as an attachment in your email.

The manual is 3.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood Skye 5

Charnwood Skye 5 User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info