Ensure that the peat is well dried before use. Burning wet
peat will give rise to heavy tar deposits and reduced outputs.
PETROLEUM COKE IS NOT SUITABLE FOR USE ON
THIS APPLIANCE, ITS USE WILL INVALIDATE THE
GUARANTEE.
At first you may find it helpful to try several fuels to find the
most suitable. If you are unable to obtain the fuel you want,
ask your supplier or an approved fuel distributor to suggest
an alternative.
This stove is not designed to burn household waste. Liquid
fuels are not to be used on this appliance.
NOTE: This appliance has been approved by HETAS as a
continuous operating appliance for burning smokeless fuel.
DOOR OPERATION
Use the spanner type tool to open and close the doors. Turn
the knob on the right hand door anti-clockwise to open and
clockwise to close. When closing the doors do not push on
the enamel with the tool as this can chip the enamel, instead
push the doors on the door knobs. When the fire is alight,
HETAS approval does not cover the use of other fuels either
alone or mixed with wood logs nor does it cover the
instructions for use of other fuels.
GENERAL
FUELS
Before lighting the fire, check with the installer that the work
and checks described in the installation instructions have been
carried out correctly and that the chimney has been swept, is
sound, and free from any obstructions.
Do not light the fire before the boiler and heating system has
been filled with water, as this can cause damage to the boiler.
WARNING: There must not be an extractor fan fitted in the
same room as this appliance as this can cause the appliance to
emit smoke and fumes into the room.
If the appliance is fitted in place of an open fire then the
chimney should be swept one month after installation to clear
any soot falls which may have occurred due to the difference in
combustion between the appliance and the open fire.
Do not use an aerosol spray on or near the stove when it is
alight. There is a risk of explosion or flash ignition of the spray.
When using the fire in situations where children or infirm
people are present please use a fire guard to prevent
accidents. The fire guard should be manufactured in
accordance with BS 8423:2010. This appliance has been
designed to conform with BS EN 13229 and BS EN 13240.
Ancit (Phurnacite Plus),
Anthracite Large Nuts, Centurion, Cosycoke, Extracite,
Maxibrite, Phurnacite, Sunbrite Doubles.
The above fuels are all suitable for use in smoke controlled
areas. In other areas the following fuels may also be burnt:
Wood
Only dry well seasoned wood should be burnt on this
appliance as burning wet unseasoned wood will give rise to
heavy tar deposits. For the same reason hard wood is better
than soft wood. Burning wet unseasoned wood will also result
in considerably reduced outputs. The wood should be cut and
split and then left to season in a well ventilated dry place for at
least one year but preferably two years before use.
This stove has obtained the approval of HETAS Ltd for burning
only the following Smokeless Fuels:
4
®
charnwood
OPERATING INSTRUCTIONS
1
2
3
4
5
0
Fig. 1. Thermostat Control
Control
Air Inlet
Knob
Damper
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood LA50iB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood LA50iB in the language / languages: English as an attachment in your email.

The manual is 0.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info