fuel, and scrape the boiler faces clean. Lift out the deepening
bar and front firebar. Fit the brick into the fire with the thick
part of the brick at the bottom and the sloping face at the
front as shown on the parts list. Push the brick hard up against
the rear face of the boiler. The brick should rest on the side
fireplates and should be clear of the grate bars. Replace the
front firebar and deepening bar.
As the brick is not cemented into position, fitting and
removing it should only take a few minutes.
TROUBLE SHOOTING
Fire Will Not Burn
Check that:
a) the air inlet is not obstructed in any way,
b) chimneys and flueways are clear,
c) a suitable fuel is being used,
d) there is an adequate air supply into the room,
e) an extractor fan is not fitted in the same room as the fire.
Fire Blazing Out Of Control
Check that:
a) the doors are tightly closed,
b) the thermostat knob is turned down to the minimum
setting,
c) the air inlet damper is closed (at the bottom left of the
appliance), and that it is not prevented from closing completely
by a piece of ash,
d) a suitable fuel is being used,
e) the door seals are in good condition.
Over-Firing
If the fire is over-fired it will cause premature failure of the
internal fire parts. Overfiring is occurring when any internal
parts of the fire begin to glow red. To prevent over-firing
ensure that:
a) the door seals are kept in good condition, and that the
doors are sealing correctly,
b) the thermostat on the fire is working correctly,
c) a suitable fuel is being used,
d) the fire is not fitted onto a heating system which is too
large.
Fume Emission
Warning Note: Properly installed and operated this
appliance will not emit fumes. Occasional fume from de-
ashing and re-fuelling may occur. Persistant fume emision is
potentially dangerous and must not be tolerated. If fume
emission does persist then the following immediate actions
should be taken:
A) Open doors and windows to ventilate the room.
B) Let the fire out and safely dispose of fuel from the
appliance.
C) Check for flue or chimney blockage, and clean if
required.
D) Do not attempt to relight fire until cause of fume has
been identified, if necessary seek professional advice.
The most common cause of fume emission is flueway or
chimney blockage. For your own safety these must be kept
clean.
Freezing
Do not light the fire if there is any possibility that any parts of
the system may be frozen.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney
fires should not occur. However, if a chimney fire does occur
turn the control knob to the minimum setting, and tightly
close the doors of the appliance. This should cause the
chimney fire to go out in which case the control should be
kept at the minimum setting until the fire in the appliance has
gone out. The chimney and flueways should then be cleaned.
If the chimney fire does not go out when the above action is
taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully
examined for any damage. Expert advice should be sought if
necessary.
Lack of Heat To Radiators / Hot Water
7
®
OPERATING INSTRUCTIONS charnwood
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood LA 30iB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood LA 30iB in the language / languages: English as an attachment in your email.

The manual is 2.12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info