(see 3), the front firebar.
Different types of sweeps brushes are available to suit different
flueways. For standard brick chimneys a wire centre sweeps brush
fitted with a guide wheel is recommended. For prefabricated
insulated chimneys the manufacturers instructions with regard to
sweeping should be consulted.
Check that:
a) the air inlet at the rear of the stove is not obstructed in any way,
b) chimneys and flueways are clear,
c) a suitable fuel is being used,
d) there is an adequate air supply into the room,
e) an extractor fan is not fitted in the same room as the stove,
f) there is sufficient draw in the chimney, (once the chimney is warm a
draught reading of at least 0.10 inches (2.5mm) water gauge (25 Pa)
should be obtained).
Keeping the glass clean requires a certain amount of experimentation
due to the differences in the draw of different chimneys. The
following points should be noted and with a little care should enable
the glass to be kept clean in most situations:
a) The airwash relies on a supply of heated air to keep the glass clean.
Therefore, when lighting the stove, allow the firebed to become well
established before closing the air control. This also applies when re-
fuelling the stove.
b) When re-fuelling, keep the fuel as far back from the front firebar
Fig. side fireplates, and
TROUBLE SHOOTING
Fire Will Not Burn
Blackening of Door Glass
as possible, do not try to fit too much fuel into the firebox.
c) Wet wood or logs overhanging the front firebars will cause the
glass to blacken.
d) There is a bypass slide that can be adjusted to suit the particular
installation. This allows a small amount of airwash air to enter the
stove even when the air control is closed. This can be adjusted to help
with keeping the glass clean when the fire is slumbering.
It is always more difficult to keep the glass clean when running the
stove very slowly for long periods.
Check that all flue connections and the blanking plate are well sealed.
It is also important that the chimney draw is sufficient (when the
chimney is warm a draught reading of at least 0.10 inches water
gauge (25 Pa) should be obtained), and that it is not affected by
down-draught.
Occasionally some blackening of the glass may occur below the level
of the front firebars. This will not obscure the view of the fire or
affect its performance.
The most common cause of fume emission is flueway or chimney
blockage. For your own safety these must be kept clean.
Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions
given under Warning Noteabove.
Check that:
a) The doors are tightly closed.
b) The air control is pushed in.
Fume Emission
Fire blazing out of control
Warning Note: Properly installed and operated this appliance will
not emit fumes. Occasional fume from de-ashing and re-fuelling
may occur. Persistent fume emission is potentially dangerous and
must not be tolerated. If fume emission does persist, then the
following immediate actions should be taken:
a) Open doors and windows to ventilate the room, and then leave
then premises.
b) Let the fire go out.
c) Check for flue or chimney blockage, and clean if required.
d) Do not attempt to re-light the fire until cause of fume has been
identified, if necessary seek professional advice.
CO Alarm
Lift throat plate at front,
then pull forward and
swing down.
Fig. 3. Throat Plate
OPERATING INSTRUCTIONS
®
charnwood
7
I
I S L A N D
IIIII
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood Island I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood Island I in the language / languages: English as an attachment in your email.

The manual is 0,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood Island I

Charnwood Island I User Manual - Dutch - 19 pages

Charnwood Island I User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info