domestic hot water. These thermostats are available from ourselves if
you are unable to obtain them locally.
There are several ways of connecting the stove to the flue. These are
illustrated in figures 8 to 11.
If a top flue connection (as shown in Fig. 10) or the vertical rear flue
connector (shown in Fig. 11) is used, then the chimney may be swept
through the appliance.
If the rear flue connection is used, the front throat plate (Item 16 on
the Parts List) must be removed. It is not used in this configuration.
Horizontal lengths of flue must be kept to a minimum and should not
be more than 150mm. The sealing face of the flue collar should be
coated with fire cement before fixing to the body of the stove using
the two screws provided. The blanking plate must be removed, sealed
with fire cement and refitted, care being taken to ensure that the fold
on the clamping plate is in line with the lugs on the firebox as shown
on the label on the clamping plate (see Fig. 12). Ensure that the
clamping plate does not prevent the throat plate from seating
correctly. All flue connections must be well sealed.
It is possible to pass a 16 inch diameter sweeps brush through the
appliance but in most back outlet installations it will be necessary to
have a soot door to enable the chimney to be swept. This may either
be in the actual brickwork of the chimney or in the register plate.
Various types and positions of soot doors are shown in figures 8-11.
Before lighting the fire check the cold setting distance of the
thermostat. This is fitted under the firebox.
CONNECTIONS TO FLUES
SOOT DOORS
THERMOSTAT
With the control knob at the minimum setting the flap should be just
closed as shown in Fig. 13. To adjust the distance slacken the locking
nut and adjust as necessary. When set correctly re-tighten the locking
nut. Ensure that the flap opens and closes freely as the knob is
turned, and that the opening is completely covered when the flap is
closed.
Before initial lighting the following points should be checked:
1. The bottom grate bars must all be fitted and should move freely
and easily when the riddling mechanism is operated.
2. The plates round the sides and back of the grate must be in
position and sitting correctly.
3
PRE LIGHTING CHECK
COMMISSIONING
The throat plate must be fitted in the roof of the appliance and
should be checked to ensure that it has not become dislodged in
transit. The method of location and positioning of the throat plate is
shown in Fig. 4.
4. The central heating and hot water system must be correctly
connected and filled.
On completion of the installation and after allowing a suitable period
of time for the fire cement and mortar to dry out, the stove should
be lit and checked to ensure that smoke and fumes are taken from
the appliance up the chimney and emitted safely. Also check all joints
and seals. If the rear flue outlet is used, ensure that the front throat
plate (Item 16 on the Parts List) has been removed. On completion of
the installation and commissioning please leave the operating
instructions with the customer and advise them on the use of the
appliance.
Fig. 13. Thermostat Setting
Thermostat Flap
Locking Nut
Flap just closed with
knob at minimum
Thermostat
Arm
INSTALLATION INSTRUCTIONS
®
charnwood
I S L A N D
12
Blanking Plate
Clamping Plate
with fold horizontal
Back of the Stove
Seal Blanking Plate
with fire cement
Fig. 12. Flue Blanking Plate.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood Island 3B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood Island 3B in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood Island 3B

Charnwood Island 3B User Manual - Dutch - 17 pages

Charnwood Island 3B User Manual - Dutch - 17 pages

Charnwood Island 3B User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info