the slot in the top of the tool before lifting (See Fig.3). Care should
be taken to ensure that ash is cool before emptying it into plastic
liners or bins.
To make ash removal easier there is a special Charnwood ash carrier
available. This may be purchased from your supplier or, in case of
difficulty, from Charnwood.
When loading the stove take care not to smother the fire, instead fill
the firebox in two stages waiting between each stage for the flames
to appear above the fire.
After a period of slumbering always turn the air control up to
maximum and wait until flames appear above the fuel bed before
opening the doors.
Burning coal will produce more soot deposits than other fuels,
especially if the fire is run at low levels for long periods. It is therefore
vital to clean the throat plate regularly, weekly cleaning is
recommended. Please also note that some blackening of the glass
may occur when burning coal.
Never fully close the Airwash control when burning coal.
The grate should be kept in the wood burning position and should
not be riddled until the ash becomes so deep that it begins to block
the passage of air into the firebox at the side of the grate. When this
is the case do not remove all of the ash using the riddling mechanism
but keep a layer about half an inch thick as this enables the wood to
burn more effectively. When burning wood or peat use the airwash
control in the same way as described (see "CONTROLLING THE
FIRE")
SPECIAL POINTS WHEN BURNING COAL
SPECIAL POINTS WHEN BURNING
WOOD AND PEAT
When lighting the fire a few small dry logs with a good
amount of kindling will help to get the fire up to temperature quickly.
OVERNIGHT BURNING
MAINTENANCE
For overnight burning the fire doors must be closed. Use large logs
rather than small ones.
If the fire is very low then it may be necessary to add a little fuel and
turn the thermostat control up to maximum for a brief period until
the fire is burning brightly before filling with fuel. When the new fuel
has ignited, the thermostat control should be turned down to the
required setting. If the central heating pump is off overnight then the
thermostat may be left at the same setting for both day and night
operation. If the central heating pump is on overnight then set the
thermostat control to give the required level of heating. Some
experimentation will be necessary to find the settings most suitable
for the particular fuel used and the draw on the chimney.
To revive the fire, add some small logs and open the thermostat
control to maximum. When the fire is burning well load on more fuel
as necessary and move the thermostat control to the desired setting.
The stove is finished with a high temperature paint which will
withstand the temperatures encountered in normal use. This may be
cleaned with a damp lint-free cloth when the stove is cold. Should re-
painting become necessary then special high temperature paints are
available from your supplier or from Charnwood.
The glass in the door is a special ceramic glass which is able to
withstand high temperatures. Before cleaning the glass open the door
and allow it to cool. Clean the glass using a damp cloth and then wipe
over with a dry cloth. Any stubborn deposits on the glass may be
removed with a proprietary stove glass cleaner or ceramic hob
cleaner. Some deposits on the glass may be burnt off simply by
running the fire at a fast rate for a few minutes. Do not use abrasive
cleaners or pads as these can scratch the surface which will weaken
the glass and cause premature failure. Aerosol spray cleaners should
not be used near the appliance whilst it is under fire.
If the fire is going to be out of use for a long period (for instance in
the summer) then to prevent condensation, and hence corrosion, the
air control should be left fully open and the fire door left ajar. It is
also advisable to sweep the chimney and clean out the fire. Spraying
the inside of the door and firebox with a light oil, such as WD40, will
also help to keep all internal parts working well.
After long periods where the fire has been out of use, the chimney
and appliance flueways should be cleaned before lighting.
Cleaning
Cleaning the Glass
When Not in Use
Fig. 3. Ashpan Removal
Tongue must be visible to
ensure correct tool location.
1
2
®
5
charnwood
OPERATING INSTRUCTIONS
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood Cove 2B at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood Cove 2B in the language / languages: English as an attachment in your email.

The manual is 0,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood Cove 2B

Charnwood Cove 2B User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info