CONNECTIONSTOFLUES
Thestovemustbeconnectedtotheflueusingfluepipeofthe
followingsizes:
Iftheoptionalverticalrearflueconnectorisusedthenthechimney
maybesweptthroughtheappliance.
Horizontallengthsoffluemustbekepttoaminimumandshouldnot
bemoreinlengththanthefluediameter.
Thestovecomeswiththeblankingplatefittedtothetopflueoutlet.
Thesealforthe outletisa180mmdiaringofropeseal.Theseal
forthe outletisalengthofadhesivebackedfibrewebbing
suppliedwithinstructions.Thisisappliedtothefluecollarorthe
VerticalRearFlueadapterforrearoutletinstallations.Fortopoutlet
installations,theblankingplatemustberemoved,havethewebbing
fittedto itssealingface,andfittedtotherearflueoutlet.
StoveModelC-Four&C-Five.....................125mm(5")i/dpipe.
StoveModelC-Six,C-Seven&C-Eight........150mm(6")i/dpipe.
top
rear
Thismaybestainlesssteel,castiron,orthickwallsteelpipe.Straight
lengthsofCharnwoodPipetomatchthestoveareavailableif
required.
Thereareseveralwaysofconnectingthestovetotheflue.Theseare
illustratedinFigs.4to7.
Ensurethat
thefoldontheclampingplateisinlinewiththelugsonthefireboxas
showninFig8.Ensurethattheclampingplatedoesnotpreventthe
throatplatefromseatingcorrectly.Allflueconnectionsmustbewell
sealed.
Fortopoutletinstallationsonthe thefluecollar
deflectormustbefittedatthesametimeasthefluecollarbecauseit
usesthesameboltstosecureittothestove.Thelongestlengthofthe
fluecollardeflectormustbealignedwiththefrontofthestoveas
showninFig9.
CFive,Six&Seven
SOOTDOORS
Itispossibletopassa16inchdiametersweepsbrushthroughthe
appliancebutinmostbackoutletinstallationsitwillbenecessaryto
haveasootdoortoenablethechimneytobeswept.Theoptional
verticalrearflueconnectordoesallowthechimneytobeswept
throughthestove.
Sootdoorsmayeitherbeintheactualbrickwork
ofthechimneyorintheregisterplate.Variouspositionsofsoot
doorsareshowninFigs.4to7.
UNPACKINGTHESTOVE
Thestovearrivesboltedandshrink-wrappedtoitspallet.Theremust
beadequatefacilitiesforunloadingandmanoeuvringintoposition
Thewrappingisfirstremoved,thenthestovereleasedfromthepallet
byeitherremovingthesinglebolt(C-4)or4palletbolts(C-5toC-8)
11
®
INSTALLATIONINSTRUCTIONS
RegisterPlate
WithSootDoor
Alternative
SootDoorPositions
Fig.7.HorizontalRegisterPlateWithOptional
VerticalRearFlueConnector
Fig.8.FlueBlankingPlate.
BlankingPlate
Clampingplatefinishes
flushwithinsidefaceof
fireboxtopandbottom.
withGlassFibreWebbing
SealBlankingPlate
GlassFibreWebbing
BlankingPlate
BackofStove
ClampingPlate
M8Nut
FlueCollar
Ropeseal
FlueCollar
Front of Stove
Deflector
Fig.9.FlueCollarDeflectorfitting.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Charnwood C Four at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Charnwood C Four in the language / languages: English as an attachment in your email.

The manual is 1,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Charnwood C Four

Charnwood C Four User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info