Remove the tube.
Correct use
The RPD10 - RPD40 tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems. They serve to
open and close these systems and replace the person that is usually operating the installation. Therefore, tubular drives may only be
installed in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired. Replace defective parts. This
guarantees safe operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to
property or consequential injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those
mentioned above or due to changes made to the equipment affecting the safety of the given system. The details stipulated in the Operating
Instructions in respect of the operation and repair of the system require strict observance. Neither the manufacturer nor the supplier assumes
any liability for personal injury, damage to property or consequential injury or damage occurring as a result of non-compliant actions.
In compliance with standard EN 60 335-2-97:2000, the cable connecting the drives to the mains cable must be laid internally.
According to DIN 18073 shuter box lid must always be easily accessible and removable.
RPD40
16m
2
12m
2
7m
2
20m
2
Carton Contents
1. Motor (1)
2. • Adjuster pin (2)
• Drive adapter safety catch (3)
• Square pin (RPD10) (4)
• Square pin (RPD15 - RPD40) (5)
• Shaft adapter (6)
• Wall bracket (7)
3. Manual
Performance features
Model
RPD10
RPD15
RPD25
RPD40
Diameter
(mm)
35
45
45
45
Torque
(Nm)
10
15
25
40
Speed
(rpm)
17
15
15
15
Operating
Voltage
(V)
230
230
230
230
Frequency
(Hz)
50
50
50
50
Current
input
(A)
0,53
0,60
0,83
0,86
Motor
Rating
(W)
121
133
191
198
Operating
time
(min)
4
4
4
4
Limit Switch
Range
(revolution)
40 +/- 1
22,5 +/- 1
22,5 +/- 1
22,5 +/- 1
Max. area (area = length x breadth)
PVC
ALU
WOOD
AWNING
RPD10
5m
2
4m
2
2m
2
RPD15
7,5m
2
6m
2
3m
2
RPD25
11m
2
9m
2
5m
2
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR CHECKING PURPOSES!