Fully unroll the shutter (a). Remove the shutter material from
the tube (b). Remove the manual control (c).
C
B
a
c
b
Remove the tube.
Correct use
The RPD10 - RPD40 tubular drives are designed for the exclusive purpose of operating shutters and sun-blind systems. They serve to
open and close these systems and replace the person that is usually operating the installation. Therefore, tubular drives may only be
installed in faultless shutter- or sun-blind systems. Rough-running systems have to be repaired. Replace defective parts. This
guarantees safe operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the manufacturer nor the supplier assumes any liability for personal injury, damage to
property or consequential injury or damage occurring as a result of the use of the control units and / or drives for purposes other than those
mentioned above or due to changes made to the equipment affecting the safety of the given system. The details stipulated in the Operating
Instructions in respect of the operation and repair of the system require strict observance. Neither the manufacturer nor the supplier assumes
any liability for personal injury, damage to property or consequential injury or damage occurring as a result of non-compliant actions.
In compliance with standard EN 60 335-2-97:2000, the cable connecting the drives to the mains cable must be laid internally.
According to DIN 18073 shuter box lid must always be easily accessible and removable.
RPD40
16m
2
12m
2
7m
2
20m
2
Carton Contents
1. Motor (1)
2. • Adjuster pin (2)
Drive adapter safety catch (3)
• Square pin (RPD10) (4)
• Square pin (RPD15 - RPD40) (5)
• Shaft adapter (6)
• Wall bracket (7)
3. Manual
Performance features
Model
RPD10
RPD15
RPD25
RPD40
Diameter
(mm)
35
45
45
45
Torque
(Nm)
10
15
25
40
Speed
(rpm)
17
15
15
15
Operating
Voltage
(V)
230
230
230
230
Frequency
(Hz)
50
50
50
50
Current
input
(A)
0,53
0,60
0,83
0,86
Motor
Rating
(W)
121
133
191
198
Operating
time
(min)
4
4
4
4
Limit Switch
Range
(revolution)
40 +/- 1
22,5 +/- 1
22,5 +/- 1
22,5 +/- 1
Max. area (area = length x breadth)
PVC
ALU
WOOD
AWNING
RPD10
5m
2
4m
2
2m
2
RPD15
7,5m
2
6m
2
3m
2
RPD25
11m
2
9m
2
5m
2
INSTALLATION
Rough- in or install conduit pipe to the connector box for the electrical connecting line according to local building and electrical codes.
THE DRIVE IS PREMOUNTED. THE DESCRIPTION IS FOR CHECKING PURPOSES!
A
RA15, RA 35, RA45, RA55
2
4
RA5
1
Series
RA5, RA15, RA35, RA45, RA55
3
6
6
7
5
RPD10
RPD15, RPD25, RPD40
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chamberlain RPD15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chamberlain RPD15 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 8,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info