en-1
IMPORTANT SAFETY RULES - SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS FOR THE USER
Caution! Non-compliance can result in serious injury.
Any work on the electrical installation including servicing
may only be performed by a qualified electrician.
Do not allow children to play with the controls.
Check shutter or sun-blind system regularly for signs of
wear and damage. Damaged systems should not be
used under any circumstances until such time as they
have been repaired.
Observe shutter or sun-blind system carefully whilst in
operation.
Switch off shutter or sun-blind system and disconnect
from mains supply, if any servicing or cleaning has to
be done either on the system itself or in its immediate
vicinity.
Ensure that the motor is accessible after installation
(DIN 18073).
Ensure sufficient room (at least 40 cm) is left between
any moving parts and nearby objects.
Ensure system cannot trap or cut persons and secure
relevant parts.
Observe safety margins as stipulated in DIN EN 294.
Please consult Chamberlain product information for further
details.
IMPORTANT SAFETY INSTRUCTIONS FOR THE
FITTER
Caution! Non-compliance can result in serious injury.
Observe EN 60 335-2-97:2000 Safety Instructions in
full.
Any work on the electrical installation may only be
performed by a qualified electrician.
When electrical or electronic systems and appliances are
in operation, certain components are live, which can
constitute a risk. Any touching of and work performed on
the equipment by persons not qualified to do so or non-
compliance with safety instructions can result in personal
injury or damage to property.
All the standards and regulations applying to electrical
installations must be observed.
Only those spare parts, tools and other equipment as have
been approved by Chamberlain may be used.
Neither the manufacturer nor the supplier assumes any
liability for personal injury, damage to property or
consequential injury or damage occurring as a result of the
use of non-approved third party products or changes made
to any accessories.
Prior to performing installation work, de-activate all
connections and control facilities that are not absolutely
essential for operation of the given system.
Fit control facilities within sight of the product to be
controlled at a height of at least 1.5 m.
Ensure sufficient room is left between any moving parts and
nearby objects.
Torque rating and duty cycle must comply with the
requirements of the product to be driven
Technical data - torque rating and duty cycle details can be
found on the tubular drive's data plate.
Before You Begin
1. Carefully read all the information contained in this Owner’s Manual
before beginning installation procedures.
2. Check the shutter to be sure it is not broken or damaged, and that it
opens and closes smoothly.
3. Determine whether the motor needs to be installed on the left side
(a) or the right side, (b) of the shutter – Figure . Always choose
the shorest possible distance to the next junction box as wires must
not be laid inside the shutter box.
4. Ensure that the motor can be pushed in as far as the stop. The limit
switch is controlled by the plastic ring which must be pushed
fully on.
E
Correct use
The RA5 - RA55 tubular drives are designed for the exclusive
purpose of operating shutters and sun-blind systems.
They serve to open and close these systems and replace the
person that is usually operating the installation.
Therefore, tubular drives may only be installed in faultless
shutter- or sun-blind systems. Rough-running systems have to
be repaired. Replace defective parts. This guarantees safe
operation and avoids damage during opening or closing.
Any other form of usage is deemed to be incorrect. Neither the
manufacturer nor the supplier assumes any liability for personal
injury, damage to property or consequential injury or damage
occurring as a result of the use of the control units and / or drives for
purposes other than those mentioned above or due to changes made
to the equipment affecting the safety of the given system.
The details stipulated in the Operating Instructions in respect of the
operation and repair of the system require strict observance. Neither
the manufacturer nor the supplier assumes any liability for
personal injury, damage to property or consequential injury or
damage occurring as a result of non-compliant actions.
In compliance with standard EN 60 335-2-97:2000, the cable
connecting the drives to the mains cable must be laid internally.
According to DIN 18073 shuter box lid must always be easily
accessible and removable.