555437
40
Zoom out
Zoom in
Previous page
1/44
Next page
39
DIAGNOSTIC CODE
SYMPTOM SOLUTION
Up Arrow
Flash(es)
Down Arrow
Flash(es)
4 1-4 Door is moving stops or reverses. Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock,
correctas needed. Ifthe door is binding or sticking contact a trained door systems technician. Ifdoor is not
binding or sticking attempt to reprogram travel (refer to page 28).
4 5 Opener runsapproximately6-8",stops and reverses. Communication error to travel module. Check travel module connections, replace travel module if
necessary.
4 6 The garage door opener will not close and the light
bulbs flash.
Safety sensors are misaligned or were momentarily obstructed.Realign both sensors to ensure both LEDs
are steadyand not flickering.Make sure nothing is hanging or mounted on the door that would interrupt
the sensor’s path while closing.
The garage door opener can beep for several reasons:
Garage door opener has been activated through a device or feature such as Timer-to-
Close or garage door monitor, see page 32.
My remote control will not activate the garage door:
Verify the lock feature is not activated on the door control.
Reprogram the remote control.
If the remote control will still notactivate the door checkthe diagnosticcodes to ensure
the garage door opener is working properly.
My door will not close and the light bulbs blink on my motor unit:
The safetyreversing sensor must be connected and aligned correctlybefore the garage
door opener will move in the down direction.
Verify the safety sensors are properly installed, aligned and free ofany obstructions.
My garage door opener light(s) will not turn off when the door is open:
The garage door opener is equipped with a feature that turns the lighton when the safety reversing sensors
have been obstructed or when the motion sensor on the door control detects movement in the garage. These
features can be disabled using the door control, see page 33.
My neighbor’s remote control opens my garage door:
Erase the memory from your garage door opener and reprogram the remote control(s).
The LEDs on the door control blink:
If you have a Smart Control Panel installed and the TTC is set to a custom time,press the ONbutton on the
Premium Motion-Detecting Control Panel to setthe time properly.
My vehicle's Homelink
®
is not programming to my garage door opener:
Depending on the make,model,and year of your vehicle an external adapter may be required. Visit
www.homelink.com for additional information.
Troubleshooting
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Chamberlain PD612EV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Chamberlain PD612EV in the language / languages: English as an attachment in your email.

The manual is 4,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info