740788
8
Zoom out
Zoom in
Previous page
1/16
Next page
8
E
X
TRAC
T
OR H
O
O
D
Dear Customer,
Thank you for buying our hood. Please read these instructions carefully
for its optimum installation, use and maintenance.
Notes: The gures mentioned in this manual are in the rst pages.
This hood is designed for tting in a cabinet or on some other support.
Warning: consult local regulations regarding fumes outlets. Do not connect
the hood to a fume, ventilation or hot air duct. Conrm that room ventilation
is appropriate with the local authorities. Make sure
the maximum air extraction ow rate for the appliances in the room
does not exceed 4 Pa (0.04 mbar).The room must have adequate
ventilation if an extractor hood is used simultaneously with appliances
that run on gas or other fuels. The evacuated air must be extracted
through ducts that are used for evacuating fumes from appliances that
run on gas or other fuels. Regulations regarding air extraction must be
complied with.
This product in intended for HOUSEHOLD USE only.
Use a rigid PVC pipe with a min. Ø l20 mm to evacuate fumes outside.
The above restrictions do not apply to hoods with no fumes outlet to outside
(recirculation system with activated charcoal lter).
Install the hood in line with the instructions on the template.
For gas cooking appliances only: the minimum distance to the hood
must be at least 65 cm.
Warning: Failure to install the screws or xing device in accordance
with these instructions may result in electrical hazards.
INSTALLATION
The cooker hood is supplied with
3 Spacer (F, H)
4 Screws (C)
2 Bulbs
To xing the Hood, use the 4 screws (C) Ø6mm supplied with the hood.
Close the space that remains between the hood and the wall,
adjunsting the spacer (F).
Before completing any connection, make sure the house voltage
corresponds with the voltage indicate on the data label.
Connecting the hood to the grid
Warning: before connecting the hood: switch o the electricity supply and
check that the supplied voltage and frequency coincide with that indicated
on the appliance nameplate.
If the extractor hood has a plug, connect it to a power socket in line with applicable
regulations, located in an accessible area.
If the hood does not have a plug, connect it directly to the electrical grid, protected
by a separator device accessible for disconnection, in line with local regulations.
The connection to the electrical mains must be made as follows:
BLUE………………………..”N” NEUTRAL
BROWN……………………..”L” LIVE
GREEN AND YELLOW……(simbolo tierra) EARTH
If the terminals of the plug are unmarked or if you are in any doubt consult a
qualied electrician.
If it is not supplied t a plug normalized in the cord for the load showed on the
rating plate.
USE OF THE HOOD – SAFETY
Warning: the hood may stop working during an electrostatic discharge (e. g.
lightning). This involves no risk of damage. Switch o the electricity supply to
the hood and reconnect after one minute.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
To avoid the risk of re, clean the metal lter regularly, permanently control pans
containing hot oil and do not ambé food underneath the hood.
Do not use the hood if it shows signs of damage or imperfection. Contact an ocial
distributor or authorised dealer.
Accessible parts may heat up when using cooking appliances.
Use of the hood - Control panel (look for the symbol in the gures)
Touch panel TC5V
1- Extractor fan on and o.
2- Extractor fan speed - button: speed SILENT, 1, 2, 3 and TURBO. In panels with
TURBO (T) button, Turbo speed only will work during 5 minutes, once it runs out,
the speed will decrease to 3rd speed.
Turbo speed only will work during 5 minuts, once it runs out, the speed will decrease
to 3th speed.
3- Enable and disable extractor fan timer.
4- Lighting on and o.
5- Button to decrease the light intensity
6- Button to increase the light intensity
Timer: the extractor fan works for 4 min. at the current speed and another 4 min. at
each of the lower speeds until it stops and the lighting switches o.
SUCTION VERSION
If the hood is to be installed as a SUCTION hood, connect the plastic
outlet piece (A) supplied with the hood (120mm diameter pipe for
better performance and lower noise levels.
FILTERING VERSION (INTERNAL RE-CYCLING)
When there is no exhaust duct for venting out-door, you can use a carbon lter (D).
The air is depurate by the lter and put again in the surrounding.
The air is released in the room through a connecting pipe, which goes through the
hanging cupboard and us connected to the connecting ring supplied (A) Fig 1.
To use the appliance in this version, proceed as follows:
Open the grids (E)
To proceed to change the charcoal lter (D), the screw (B)
has to be removed.
Reinstall the grids.
HOOD MAINTENANCE
Warning: always switch o the electricity supply before carrying out
maintenance work on the hood. In the event of a fault, contact an ocial
distributor or authorised dealer.
Exterior cleaning: use non-corrosive, liquid detergent and avoid the use of abrasive
cleaning products.
Grease lters: to avoid res, clean thoroughly once a month. To do so, remove the
lters and wash with hot water and detergent. If using a dishwasher, position the
lters vertically to prevent solid remains from depositing on them.
Activated charcoal lters: replace the every 2 months.
Important: increase the lter cleaning/replacement frequency if the hood
is used for more than 2 hours a day. Always use genuine lters from the
manufacturer.
Bulb replacement (look for the s y m b o l in the gures)
Warning: do not handle the bulbs until the electricity supply has been
switched o and they have cooled.
Important: use new bulbs according to that indicated on the hood nameplate.
Use bulbs with an aluminium reector to replace halogen bulbs. Do not use
dichroic bulbs - risk of overheating.
On cooker hoods equipped with tungsten lamps, the lights should only be used
during operation of the motor. They should not be left on permanently and used
as a light source.
Legal information
The manufacturer:
- Declares that this product meets all basic requirements regarding low-voltage
electrical equipment established in Directive 2006/95/EC of 12 December 2006
and electro-magnetic compatibility established in Directive 2004/108/EC of 15
December 2004.
- Is not responsible for any failure to observe the instructions given in this manual
and current safety regulations for the correct use of the equipment.
- Reserves the right to make any modications to the equipment or this manual
without prior notice.
Contact our ocial distributor should you require technical assistance or additional
information on our products.
EN
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cata TF 7600 WH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cata TF 7600 WH in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info