487635
37
Zoom out
Zoom in
Previous page
1/40
Next page
TE-M80
Electronic Cash Register
Eu
UK
Di
START-UP is QUICK and EASY!
Simple to use!
15 departments
Automatic Tax Calculations
Calculator function
User's Manual
GM
TE-M80-S
TE-M80-M
INTRODUCTION
2
E
INTRODUCTION
Thank you very much for purchasing this CASIO electronic cash register.
START-UP is QUICK and EASY!
Part-1 of this user's manual can help you make a quick start.
Once you have mastered the QUICK START operations, you will undoubtedly want to
expand your use of this machine by studying other sections of Part-2.
Original carton / package
If for any reason, this product is to be returned to the store
where purchased, it must be packed in the original carton/
package.
Location
Locate the cash register on a flat, stable surface, away from
heaters or areas exposed to direct sunlight, humidity or dust.
Power supply
Your cash register is designed to operate on standard house-
hold current (120V, 220V, 230V or 240V; 50/60Hz). Do not
overload the outlet by plugging in too many appliances.
Cleaning
Clean the cash register exterior with a soft cloth which has
been moistened with a solution of a mild neutral detergent
and water, and wrung out.
Be sure that the cloth is thoroughly wrung out to avoid
damage to the printer.
Never use paint thinner, benzene, or other volatile solvents.
INTRODUCTION
3
E
Safety precautions
To use this product safely and correctly, read this manual thoroughly and operate as instructed.
After reading this guide, keep it close at hand for easy reference.
Please keep all informations for future reference.
Always observe the warnings and cautions indicated on the product.
About the icons
In this guide various icons are used to highlight safe operation of this product and to prevent injury to the
operator and other personnel and also to prevent damage to property and this product. The icons and
definitions are given below.
Indicates that there is a risk of severe injury or death if used incorrectly.
Indicates that injury or damage may result if used incorrectly.
Icon examples
To bring attention to risks and possible damage, the following types of icons are used.
The symbol indicates that it includes some symbol for attracting attention (including warning). In this triangle
the actual type of precautions to be taken (electric shock, in this case) is indicated.
The
symbol indicates a prohibited action. In this symbol the actual type of prohibited actions (disassembly, in
this case) will be indicated.
The symbol indicates a restriction. In this symbol the type of actual restriction (removal of the power plug
from an outlet, in this case) is indicated.
Warning!
Handling the register
Should the register malfunction, start to emit smoke or a strange odor, or otherwise behave abnormally,
immediately shut down the power and unplug the AC plug from the power outlet. Continued use
creates the danger of fire and electric shock.
Contact CASIO service representative.
Do not place containers of liquids near the register and do not allow any foreign matter to get into it.
Should water or other foreign matter get into the register, immediately shut down the power and unplug
the AC plug from the power outlet. Continued use creates the danger of short circuit, fire and electric
shock.
Contact CASIO service representative.
Should you drop the register and damage it, immediately shut down the power and unplug the AC plug
from the power outlet. Continued use creates the danger of short circuit, fire and electric shock.
Attempting to repair the register yourself is extremely dangerous. Contact CASIO service representative.
INTRODUCTION
4
E
Warning!
Never try to take the register apart or modify it in any way. High-voltage components inside the register
create the danger of fire and electric shock.
Contact CASIO service representative for all repair and maintenance.
Power plug and AC outlet
Use only a proper AC electric outlet. Use of an outlet with a different voltage from the rating creates the
danger of malfunction, fire, and electric shock. Overloading an electric outlet creates the danger of
overheating and fire.
Make sure the power plug is inserted as far as it will go. Loose plugs create the danger of electric
shock, overheating, and fire.
Do not use the register if the plug is damaged. Never connect to a power outlet that is loose.
Use a dry cloth to periodically wipe off any dust built up on the prongs of the plug. Humidity can cause
poor insulation and create the danger of electric shock and fire if dust stays on the prongs.
Do not allow the power cord or plug to become damaged, and never try to modify them in any way.
Continued use of a damaged power cord can cause deterioration of the insulation, exposure of internal
wiring, and short circuit, which creates the danger of electric shock and fire.
Contact CASIO service representative whenever the power cord or plug requires repair or maintenance.
Caution!
Do not place the register on an unstable or uneven surface. Doing so can cause the register —
especially when the drawer is open — to fall, creating the danger of malfunction, fire, and electric
shock.
Do not place the register in the following areas.
Areas where the register will be subject to large amounts of humidity or dust, or directly exposed to hot or
cold air.
Areas exposed to direct sunlight, in a close motor vehicle, or any other area subject to very high
temperatures.
The above conditions can cause malfunction, which creates the danger of fire.
Do not overlay bend the power cord, do not allow it to be caught between desks or other furniture, and
never place heavy objects on top of the power cord. Doing so can cause short circuit or breaking of the
power cord, creating the danger of fire and electric shock.
Be sure to grasp the plug when unplugging the power cord from the wall outlet. Pulling on the cord can
damage it, break the wiring, or cause short, creating the danger of fire and electric shock.
Never touch the plug while your hands are wet. Doing so creates the danger of electric shock. Pulling
on the cord can damage it, break the wiring, or cause short, creating the danger of fire and electric
shock.
Never touch the printer head and the platen.
5
E
Before you start
Contents
Getting to know your cash register ........................................................................................................... 6
Daily Job Flow........................................................................................................................................... 8
Part-1 QUICK START OPERATION ......................................................... 9
(You can operate this ECR on a basic level by reading the following sections)
1. Initialization ...................................................................................................................................... 9
2. To select the language..................................................................................................................... 9
3. To select date format and monetary mode ...................................................................................... 9
4. Loading paper .................................................................................................................................. 10
5. Basic programming for QUICK START TIME/DATE .................................................................... 11
6. Basic operation after basic programming ........................................................................................ 13
7. Daily management report................................................................................................................. 17
Part-2 CONVENIENT OPERATION .......................................................... 19
(Please keep these sections to expand your use.)
1. Various programming....................................................................................................................... 19
2. Various operations ........................................................................................................................... 32
Part-3 CALCULATOR FUNCTION............................................................ 36
1. Calculator mode ............................................................................................................................... 36
Part-4 USEFUL INFORMATION ............................................................... 38
1. Troubleshooting ............................................................................................................................... 38
2. Specifications ................................................................................................................................... 39
Operator display
Program key
Operator key
Keyboard
Drawer
Multipurpose tray
(only for TE-M80 with M drawer)
Memory protection
batteries
Roll paper
Take-up reel
Users manual
Drawer keys (2)
Rear customer display
12345&78
Unpacking
6
E
Getting to know your cash register
Note:
An error is generated
(E01 displayed)
whenever the position
of the mode switch is
changed during
registration.
The position of the mode switch controls the type of operations you can perform on the cash
register. The PROGRAM key (marked PGM) that comes with the cash register can be used
to select any mode switch setting, while the OPERATOR key (marked OP) can be used to
select OFF, REG or CAL only.
OFF
In this position, the power of the cash register is off.
REG (Register)
This is the position used for registration of normal transactions.
RF (Refund)
This is the position used for registration of refunds.
CAL (Calculator)
This is the position used for calculator mode.
PGM (Programming)
This is the position used to program the cash register to suit the needs of your store.
X (Read)
This is the position used to produce reports of daily sales totals without clearing the totals.
Z (Reset)
This is the position used to produce reports of daily sales totals. This setting clears the totals.
CAL
REG
OFF
RF
PGM
X
Z
PGM RF OFF REG CAL X Z
●● OP key
PGM key
Getting to know your cash register
Displays
Rear customer display
Operator display
1 Total/Change indicator
The total or change indicator appears when a subtotal, total or
change is obtained. These indicators are also used for depart-
ment shift level.
2 Department number display
Anytime you press a department key to register a unit price,
the corresponding department number appears here.
3 Number of repeat display
Anytime you perform repeat registration (page 13), the number
of repeats appears here.
Note that only one digit is displayed for the number of repeats.
4 Numeric display
Entered values (unit prices or quantities) and calculated val-
ues (subtotals, totals or change amount due) are displayed
here. The capacity of the display is 8 digits.
This part of the display can be used to show the current time
or date between registration (page 34).
5 Character display
In the character programming (P2) mode, it shows the last
entered character.
TOTAL
CHARACTER
CHANGE
2nd
DEPT:
3rd
2
5
3
4
1
12#45&78
A
2
3
4
12#45&78
PGM key
OP
PGM
OP key
7
E
Keyboard
Certain keys have two functions; one for
register mode and one for calculator
mode.
In this manual, we will refer to specific
keys as noted below to make the opera-
tions as easy to understand as possible:
Getting to know your cash register
7
1
0
4
8
2
00
5
9
3
.
6
FEED
DEPT
SHIFT
ERR
.
CORR
DATE
TIME
CH
CHK
PD
RC
×
%
14
9
15
10
CA AMT
TEND
11
6
12
7
13
8
C
+
1
2
×
3
÷
4
5
=
AC
MR
HELP
PAPER
SAVING
POST
RECEIPT
SUBTOTAL
NS
#
OPEN
1 43
9
2 5 6 7
A B
C D
E
F
8
G
H
I
0
J
1 l Feed key
2 Multiplication / Date time key
3 y Clear key
4 g Minus / Error correction key
5 å Department shift key
6 x Percent key
7 n Reference number/No sale key
Drawer open key
8 ?Z~>, '
Numeric keys and 2-zero key
9 " Decimal key
0 G, S, D, F, [Department keys
Department 6 through 15 are specified by pressing the
j key (once or twice) respectively as follows:
jG Department 6 jS Department 7
j[ Department 10 jjG Department 11
jj[ Department 15
A . Received on account key
B ; Euro / Paidout key
C u Charge key
D ç Check key
E o Subtotal key
F p Cash amount tendered key
Register Mode
G } Paper saving key
Paper saving key is the key to save printing paper (
Journal
compressed printing / No receipt issuing).
In these cases, the LED of this key lights.
H | Post receipt key
Post receipt key is used for issuing receipt after transac-
tion. This key is effective if the printer is defined as printing
receipts. Refer to page 33.
I { Help key
Help key is used for issuing assistant receipts such as
programming date/time, paper installation etc.
J
OPEN
Printer open key
Printer open key is used to open printer platen for setting/
replacing roll paper.
3 t AC key
6 x Percent key
8 ?Z~>, ' Numeric keys and 2-zero key
9 " Decimal key
0 HJKL Arithmetic operation keys
A / Memory recall key
F p Equal key
Calculator Mode
Normal printing
Compressed printing
DEPT01
DEPT01 T1 •2.00
DEPT02 T1 •3.00
•4.00
DEPT01
DEPT02
DEPT01 T1 •2.00
DEPT02 T1 •3.00
DEPT03 T1 •4.00
DEPT04 T1 •5.00
T2 •6.00
•1.00
8
E
Daily Job Flow
Daily Job Flow
Before opening the store
1. Plugged in?
2. Enough roll paper?
3. Date and time is correct?
4. Enough small change in the drawer?
While the store is open
1. Registrations.
2. Issuing latest daily sales total if needed.
(Generating report by mode switch to
X position.)
After closing the store
1. Issuing daily sales total.
(Resetting report by mode switch to Z
position.)
2. Picking up money in the drawer.
3. Turn the mode switch to OFF.
To lock/unlock the multipurpose tray
A. Turn the lever (1) clockwise to lock the tray (the indicator becomes red).
B. Turn the lever (1) counterclockwise to unlock the tray (the indicator becomes green).
(A)
(B)
(1)
(only for TE-M80 with M drawer)
9
Part-1
E
QUICK START OPERATION
Part-1
1. Initialization and loading memory protection battery
Important
You must initialize
the cash register
and install the
memory protection
batteries before you
can program the
cash register.
To initialize the cash register
1. Set the mode switch to OFF.
2. Plug the power cord of the cash register into an AC outlet.
3. Load the memory protection batteries.
4. Set the mode switch to REG.
To load the memory protection batteries
1. Remove the printer cover.
2. Press down on the oval just behind the printer paper inlet, and slide the battery
compartment cover toward the back of the cash register.
3. Load 3 new UM-3, R6P (SUM-3) or LR6 (AM-3) type batteries into the compartment.
Be sure that the plus (+) and minus () ends of each battery are facing in the
directions indicated by the illustrations inside the battery compartment (Figure 1).
4. Slide the memory protection battery compartment cover back into place.
5. Replace the printer paper and printer cover.
REPLACE MEMORY PROTECTION BATTERIES AT LEAST ONCE
EVERY YEAR.
(Figure 1)
2. To select the language
You can select the default printing language depending on the requirements in your area.
Example: Change the language to Spanish.
1. Set the mode switch to PGM.
2. Press the following keys.
3. To select date format and monetary mode
You can select t the date format and the monetary mode.
Example: Change the date format to Month/Day/Year, and the monetary mode to Add 0.
1. Set the mode switch to PGM.
2. Press the following keys.
Program set code number
P3 appears in mode display
Select numbers from
lists B and C.
(To end the setting)
Co
?ZXXo
Z?p
o
Language selections
A
English Z>>>
Spanish X>>>
French C>>>
German V>>>
Date format selections
B
Year/Month/Day ?
Month/Day/Year Z
Day/Month/Year X
Monetary mode selections
C
Add 0 (0. ) ?
Add 1 (0.0 ) Z
Add 2 (0.00 ) X
Select numbers from list A.
X>>>{
10
E
Part-1 QUICK START OPERATION
5 Remove the journal paper from the
take-up reel.
6 Press the printer open key and open
the platen arm.
7 Remove the core of the paper.
8 Load new paper following the instruc-
tions 1. To load journal paper.
4. Loading paper roll
Mode switch to REG
CAL
REG
OFF
RF
PGM
X
Z
REG
1. To load journal paper
1 Pressing down the printer open key.
2 Open the platen arm.
3 Ensuring the paper is being fed from
the bottom of the roll, lower the roll
into the space behind the printer.
4 Put the leading end of the paper over
the printer.
5 Close the platen arm slowly until it
locks steadily.
To load receipt paper
1 In case of defining the printer as
receipt printer, follow steps 1 through
5 of To load journal paper.
2 Pass the leading end of the receipt
paper through the paper outlet of the
printer cover.
3 Tear off any excess paper.
To remove receipt paper
1 In case of defining the printer as
journal printer, follow steps 6 through
7 of To remove a journal paper.
Caution
(in handling the thermal paper)
1. Never touch the printer head and platen.
2. Unpack the paper just before your use.
3. Avoid heat/direct sunlight.
4. Avoid dusty and humid places for storage.
5. Do not scratch the paper.
6. Do not keep the paper under the following
circumstances: High humidity and tempera-
ture/direct sunlight/contact with glue, thin-
ner or a rubber eraser.
Default printer definition is journal printer.
To print receipts, please refer to 1-7-3 on
page 24 to switch the printer for receipt or
journal.
Options:Roll paper ••• P-5880T
6 Remove the printer cover by lifting up
the back.
7 Roll the paper onto the take-up reel a
few turns.
8 Set the left plate of the take-up reel
and place the reel into the register.
9 Press the l key to take up any
slack in the paper.
0 Replace the printer cover slowly.
2. To remove journal paper
1 Remove the printer cover by lifting up
the back.
2 Press the l key until approximately
20cm of the paper is fed from the
printer.
3 Cut off the roll paper.
4 Remove the take-up reel from the
printer and take off the left plate of the
reel.
platen arm
printer cover
11
Part-1
E
1. Insert the PROGRAM key (marked PGM) and rotate to PGM position.
2. Press the following keys to set the current time.
Example: 13:18 PM = 1318
Enter 4 digits
24-hour time format
3. Press the following keys to set the current date.
Example: January 8, 2004 = 040108
Enter 6 digits
Enter last 2 digits for year set. (2004 04)
4. You can set only one tax calculation system either an add-on or an add-in depending on the
laws in your area. Press the following keys to set the tax rate.
Example: Set tax rate 1 as 5.25% and tax rate 2 as 10%.
See page 25 to specify the tax system and rounding for details.
5. Press the following keys to preset tax status of departments.
Tax status for the departments are fixed as nontaxable.
Example: Set departments 1 and 2 as taxable status 1.
See page 19 to change the fixed tax status.
5.
Basic programming for QUICK START
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
PGM
Programming
P appears in mode display
Setting the current
date
Setting the current
time
Setting the tax rate
P appears in mode display
Co
?ZXBo
B"XBp
B??Cp
o
?XXBo
Z?p
B??Cp
o
Zo
?V?Z?<
y
Zo
ZCZ<
y
Minutes
Time
Day
Year
Month
Part-1 QUICK START OPERATION
(to end the time setting)
(to end the date setting)
P3 appears in mode display
Program set code No. for tax rate 1
5.25% tax rate
50 for Round off and 03 for VAT (Value Added Tax)
Add In
Procedure Purpose
Zo
.GSo
P appears in mode display
Setting the status of
departments
50 for Round off and 03 for VAT (Value Added Tax)
Add In
(to end the setting)
10% tax rate
Program set code No. for tax rate 2
12
E
6. For the Euro only
6-1. Press the following keys to define the main currency/print out currency of the subtotal.
6-2. Press the following keys to set the currency exchange rate against the Euro.
P3 appears in mode display
Setting the Euro
P3 appears in mode display
Co
XVXXo
Zp
o
Euro status
(to end the setting)
(to end the setting)
Procedure
Purpose
Euro status
(1) Main currency = Local, Print out subtotal = Local:
?
(2) Main currency = Euro, Print out subtotal = Euro: Z
(3) Main currency = Local, Print out subtotal = Both: X
(4) Main currency = Euro, Print out subtotal = Both: C
Co
Z>>>o
Z>MMCp
o
Decimal position
Exchange rate
(up to 6 digits)
Example: (Exchange rate and decimal position)
Currency exchange rate = 1 Euro in local currency
1 Euro = 1.95583 DM :
Z>BB<CB
Setting the
Australian GST
Procedure Purpose
For Australia only.
You can set some programmable options to suit the Australian GST by the following procedure.
1. Insert the PROGRAM key (marked PGM) and rotate to Z position.
2. Press the following keys to program.
?Z?ZX??Zop
If you want to cancel this operation, press o instead of p.
Procedure Purpose
For the Euro only.
You can restrict the registerable currency to the Euro only by the following procedure.
1. Insert the PROGRAM key (marked PGM) and rotate to Z position.
2. Issue all reset report including periodic data.
3. Press the following keys to set.
?Z?MX??Xop
If you want to cancel this operation, press o instead of p.
Restricting the
currency (Euro)
Part-1 QUICK START OPERATION
13
Part-1
E
Z??G
åX??[
o
B??p
CAL
REG
OFF
RF
PGM
X
Z
6. Basic operation after basic programming
Whenever an error is generated (E01 displayed), the input figures reset to 0.
Mode switch REG
REG
6-1 Open the drawer
without a sale
Note:
6-2 Basic operation
Example
n
Part-1 QUICK START OPERATION
Printout
Operation
Unit price
Department 1
Cash amount tendered
Z??G
G
C
ZCBS
o
p
6-3 Multiple registration
of the same items
Example
Multiple key
Department 1
Unit price
Quantity
Unit Price $1.00 $1.35
Quantity 2 3
Dept. 1 2
Note that repeat registration can be used with unit prices up to 6 digits long.
6-4 Charge sales
Example
Z??G
X??S
C??G
o
u
Charge key
Unit Price $1.00 $2.00 $3.00
Quantity 1 1 1
Dept. 1 2 1
You cannot perform the amount tendered operation using the u key.
NS ••••••••••
—— No sale symbol
DEPT01 •1.00
DEPT10 •2.00
TOTAL
3
.
00
CASH •5.00
CHANGE •2.00
——
Unit Price/Department No.
—— Subtotal
—— Cash amount tendered
—— Change amount due
DEPT01 •1.00
DEPT01 •1.00
3 X @1.35
DEPT02 •4.05
CASH
4
.
05
—— Repeat
—— Multiplication symbol
—— Unit price symbol
—— Department No.
DEPT01 •1.00
DEPT02 •2.00
DEPT01 •3.00
CHARGE
6
.
00
—— Charge sales
Unit Price $1.00 $2.00
Quantity 1 1
Dept. 1 10
Cash Amount
$5.00
tendered
Department 10
Departments 6 through 10 and 11 through 15 can also be registered in combination with
the å and G, S, D, F or [ keys, respectively.
The å key should be entered once for department 6 ~ 10, twice for department 11 ~ 15
just before entering unit price manually.
14
E
Part-1 QUICK START OPERATION
Printout
Operation
Example
6-5 Split cash/
charge sales
X??G
C??S
V??G
o
B??p
u
Unit Price $2.00 $3.00 $4.00
Quantity 1 1 1
Dept. 1 2 1
Cash
Amount $5.00
tendered
Z?
ZB?y
Z?
Z?BD
6-6 Corrections
Corrections can be made while you are registering the item (before you press a department
key), or after it has already been registered into the memory (by pressing a department
key).
6-6-1 Before you press
a department key
y key clears the last item entered.
2. Entered unit price first
instead of quantity and
then pressed
h.
Example
1. Entered 400 for unit price
by mistake instead of
100.
Operation
Printout
Wrong entry
Clears the last item entered.
Correct entry
Registered department 1
Unit price
Multiplication
Multiplication
Registered department 2
Clears the last item entered.
Quantity
Unit price
3. Entered 150 for unit
price by mistake instead
of 105.
Quantity
Quantity
Wrong entry
Clears the last item entered.
Correct entry
Registered department 3
Multiplication
V??y
Z??G
X??
y
B
X??S
DEPT01 •2.00
DEPT02 •3.00
DEPT01 •4.00
TOTAL
9
.
00
CASH •5.00
CHARGE •4.00
—— Cash amount tendered
—— Charge sales
DEPT01 •1.00
5 X @2.00
DEPT02 •10.00
10 X @1.05
DEPT03 •10.50
15
Part-1
E
BB?G
g
B?BG
C
XX?S
g
C
XC?S
Part-1 QUICK START OPERATION
CAL
REG
OFF
RF
PGM
X
Z
Mode switch REG
REG
g key cancels the last registered item.
6-6-2 After you pressed
a department key
Example
1. Entered unit price 550 by
mistake instead of 505
and pressed a department
key.
Operation
Printout
Wrong entry
Registered department 1
Correct entry
Cancels the last item registered.
2. Entered unit price 220 by
mistake instead of 230
and pressed a department
key.
Multiplication
Quantity
Cancels the last item registered.
Wrong entry
Correct entry
Registered department 2
DEPT01 •5.50
ERR CORR -5.50
DEPT01 •5.05
3 X @2.20
DEPT02 •6.60
ERR CORR -6.60
3 X @2.30
DEPT02 •6.90
16
E
C
X??G
;
o
ZB'
;
p
p
Part-1 QUICK START OPERATION
CAL
REG
OFF
RF
PGM
X
Z
Mode switch REG
REG
6-7-1 Registering with
currency exchange
Example
Display
Operation
Pressing ; before subtotal converts
the subtotal amount into the Euro.
Unit Price 2.00
Quantity 3
Dept. 1
Cash Amount
Euro 15.00
Tendered
Rate 1Euro = 0.5 Fr
Main currency Local (Fr)
Printout of ST Both currencies
——
Subtotal in the main currency
—— Subtotal after conversion
—— Payment in the Euro
—— Payment after conversion
——
Change in the main currency
——
Change in the sub currency
Printout
Pressing ; after amount tendered
converts the amount into the Euro. *1
Press p to finalize the transaction.
The change amount in the main
currency is shown on the display. *2
You can switch the currency of change
amount repeatedly by pressing the
p key.
1"00e
00e.
*1 If the payment is the same as the subtotal amount, you can omit this operation.
Press p key directly after the subtotal.
*2 If the payment is less than the subtotal amount, the cash register specifies it as a
partial payment and shows the balance in the main currency on the display.
1%00e
!50
#00e
3 X @2.00
DEPT01 •6.00
TOTAL
6
.
00
12
.
00
EURO
CASH ™15.00
CASH •7.50
CHANGE •1.50
EURO CG ™3.00
6-7 Currency exchange
17
Part-1
E
7. Daily management report
This section tells you the procedures to use to produce reports of the transaction data stored in the
cash register's memory.
Important
Remember that when you issue a reset (Z) report, the data that is reported is cleared from the
applicable totalizers. To view data without clearing totalizers, issue a read (X) report.
7-1 Financial report
Part-1 QUICK START OPERATION
Printout
Operation
CAL
REG
OFF
RF
PGM
X
Z
Mode switch
X
Mode switch to
(Read)
Mode switch to
(Reset )
7-2-1 Daily read/reset
report
X
Z
Printout
Operation
7-2 Daily/Periodic
read/reset
report
p
Z (Reset) report
p
—— Mode/Date/Time
—— /Consecutive No.
—— Report title
—— Gross sales No. of Items
—— Gross sales amount
—— Net sales No. of customers
—— Net sales amount
—— Cash total in drawer
—— Charge total in drawer
—— Check total in drawer
—— Mode/Date/Time
—— Consecutive No.
—— Report code/Title/Reset counter
*
—— Dept. name/No. of items
—— Amount
—— Gross sales No. of items
—— Gross sales amount
—— Net sales No. of customers
—— Net sales amount
—— Cash in drawer
—— Charge in drawer
—— Check in drawer
—— Taxable amount 1
—— Tax amount 1
—— Refund mode count
—— Refund mode total
—— CAL mode count
—— Cash sales count
—— Cash sales amount
—— Charge sales count
—— Charge sales amount
—— Check sales count
—— Check sales amount
—— Received on account total
—— Paidout total
—— Reduction amount
—— Premium/Discount amount
—— Error correct count
—— No sale count
—— Non resettable ground total *
X 07-19-2003 14:27
0072
FLASH
X
GROSS TOTAL QT 67
•270.48
NET TOTAL No 38
•271.24
CASH-INDW •197.57
CHARGE-INDW •18.19
CHECK-INDW •45.18
Z 07-19-2003 19:35
0073
0000
DAILY
Z 0012
DEPT01 QT 48
•50.10
DEPT02 QT 28
•76.40
DEPT03 QT 17
•85.80
DEPT04 QT 4
•76.00
DEPT05 QT 1
•6.80
23
DEPT15 QT 4
•3.00
------------------------
GROSS TOTAL QT 108
•316.80
NET TOTAL No 46
•325.13
CASH-INDW •199.91
CHARGE-INDW •16.22
CHECK-INDW •105.00
TAX-AMT1 •105.10
TAX1 •4.20
RF-MODE TTL No 2
•0.50
CALCULATOR No 3
------------------------
CASH No 44
•203.91
CHARGE No 3
•16.22
CHECK No 2
•105.00
RC •6.00
PD •10.00
- •0.50
%- •0.66
ERR CORR No 21
NS No 12
------------------------
GRND TTL •0000832721.20
* X (Read) report has the same contents except * marked items.
18
E
Part-1 QUICK START OPERATION
7-2-2 Periodic read/reset
report
Mode switch to or
Printout
Operation
Z?p
Z
X
Z 07-19-2003 19:50
0074
0010 PERIODIC ZZ 0001
GROSS TOTAL QT 67
•270.73
NET TOTAL No 38
•271.24
—— Mode/Date/Time
—— Consecutive No.
—— Report code/Title/Reset counter
—— Gross sales No. of items
—— Gross sales amount
—— Net sales No. of customers
—— Net sales amount
Part-2
19
E
CONVENIENT OPERATION
Part 2
1. Various programming
1-1 Unit price for
departments
Mode switch
(For Dept. 1)
P appears in mode display
(For Dept. 2)
(For Dept .13)
1-2 Rate for percent key
P appears in mode display
Zo
Z??G
XX?S
ååZZ??D
o
Z o
X"Bx
o
(To end the setting)
Unit prices within the range of 0.01~9999.99.
The rate within the range of 00.01 to 99.99%.
Zo
.G
;S
o
1-3 To change tax
status for
departments
Tax status for the departments 1~4 are initialized as nontaxable.
P appears in mode display
(To end the setting)
CAL
REG
OFF
RF
PGM
X
Z
PGM
Taxable status 1
For Dept. 1
Taxable status 2
For Dept. 2
Selections
Taxable status 1
.
Taxable status 2 ;
Taxable status 1 and 2 .;
Nontaxable status n
A
Example
Unit Price $1.00 $2.20 $11.00
Dept. 1 2 13
Example
Discount Rate 2.5%
Example
Status Taxable 1 Taxable 2
Depts. 1 2
20
E
Zo
.x
o
Normal department ?
Minus department Z
No limitation for manually entered price. ?
Maximum number of digits for manually entered price
(1 ~ 7 digits). Z ~ M
To prohibit manual price entries. < or >
Normal sale (not a single-item sale) department. ?
Set as a single-item sale department. Z
1-5 Status for percent key
1-5-1 To change taxable
status for the percent
key
The percent key is initialized as nontaxable.
Example
Change percent key registra-
tion as a taxable status 1.
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
Part-2 CONVENIENT OPERATION
1-4 Status for
department
PGM
P3 appears in mode display
(To end the setting)
Normal
department
Maximum No. of
digits to be 4
Co
?VZG
?BZåS
o
Normal
department
Maximum No. of
digits to be 5
For Dept. 1
Single item sale
department
For Dept. 7
Single item sale
department
Selections
C
A
B
P appears in mode display
(To end the setting)
Selections
Taxable status 1 .
Taxable status 2 ;
Taxable status 1 and 2 .;
Nontaxable status n
A
(For percent key)Taxable status 1
Example
Selections
ABC
1041
7051
Depts.
Part-2
21
E
1-5-2 Status for
percent key
Part-2 CONVENIENT OPERATION
The minus key is initialized as nontaxable.
Example :
Change minus key registrations
taxable status 1.
Selections
Taxable status 1 .
Taxable status 2 ;
Taxable status 1 and status 2 .;
Nontaxable status n
A
1-6 Taxable status for
minus key
Selections
Co
ZZx
o
Round up Premiums (%+)
P3 appears in
mode display
(To end the setting)
Rounding of results produced by percent key operation.
Round off (1.544=1.54; 1.545=1.55)
?
Round up (1.544=1.55; 1.545=1.55) Z
Cut off (1.544=1.54; 1.545=1.54) X
Program percent key to register discounts (%). ?
Program percent key to register premiums (%+). Z
A
B
Zo
.g
o
P appears in
mode display
(To end the setting)
Minus key
Taxable status 1
Example
Round Up
Percent %+
22
E
Co
?NXXo
???p
o
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
1-7-1 To set general
controls
1-7 General features
Part-2 CONVENIENT OPERATION
PGM
P3 appears in mode display
Select a
number
from
list C
Select a
number
from
list B
(To end the setting)
Program code No.
Select a
number
from
list A
Yes
?
No Z
Yes X
No C
Yes V
No B
Yes N
No M
A
Selections
Maintain key buffer during receipt issue in REG mode.
Selections
Selections
C
Use the ' key on a numeric keyboard. ?
Use the ' key as a 000 key. Z
B
Reset the transaction number to zero whenever a
daily reset report is issued.
Allow credit balance registration.
Yes
No
Yes
No
No
Yes
Yes
Allow partial cash amount tendered.
Allow partial check amount tendered.
No
No
?
Yes Z
No X
Yes C
No V
Yes B
No N
Yes M
Yes
No
Yes
No
Limit the last 2 digits of cash amount tendered to 00, 25,
50 and 75 when Danish rounding is specified for subtotal
and total amount.
Part-2
23
E
1-7-2 To set printing
controls
Part-2 CONVENIENT OPERATION
Co
?BXXo
????p
o
P3 appears in mode display
Select a number
from list D
(To end the setting)
Program code No.
Select a
number
from list C
Select a number
from list B
Select a number
from list A
Selections
A
Use the printer to print a journal. ?
Use the printer to print receipts. Z
Selections
C
Yes
No
Print RF mode count/amount on the daily read/reset report.
Print the grand sales total on the daily reset report.
Print the time on the receipt and journal.
Yes
?
No
Z
Yes
X
No
C
Yes
V
No
B
Yes
N
No
M
No
Yes
No
Yes
Yes
?
No
Z
Yes
X
No
C
Yes
V
No
B
Yes
N
No
M
D
No
Yes
Print the subtotal on the receipt/journal when the
subtotal key is pressed.
Skip item print on journal.
No
Yes
No
Yes
Selections
Print the consecutive number on the receipt/journal.
Selections
B
Print zero-total item on the daily/periodic read/reset reports.
Print receipt by single/double height characters.
Print total line at finalization.
Yes
?
No
Z
Yes
X
No
C
Yes
V
No
B
Yes
N
No
M
BY SINGLE
HEIGHT
BY DOUBLE
HEIGHT
BY SINGLE
HEIGHT
BY DOUBLE
HEIGHT
No
Yes
24
E
Z o
Z u
o
To print a receipt
Example
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
1-7-3 Printer switch for
receipt or journal
P appears in mode display
Print receipt
(To end the setting)
Use the printer to print a journal. ?
Use the printer to print receipts. Z
Selections
A
PGM
Printer selection to print a journal or receipts can also be set on
procedures 1-7-2 To set printing controls.
Part-2 CONVENIENT OPERATION
The printer is initialized as journal.
Part-2
25
E
1-8 Setting the tax rate
and rounding
Part-2 CONVENIENT OPERATION
P3 appears in mode display
Program set code No. for tax rate 1*
1
Tax rate specifications
A
The tax rate within the range of 0.0001 ~ 99.9999%.
Use
" key for decimal point.
Normal rounding specifications
B
Cut off to 2 decimal places. ??
(1.544=1.54, 1.545=1.54)
Round off to 2 decimal places.
B?
(1.544=1.54, 1.545=1.55)
Round up to 2 decimal places.
>?
(1.544=1.55, 1.545=1.55)
Special rounding specifications for subtotal and total amounts
C
No specifications ?
Special rounding 1 Z
0 ~ 2 0, 3 ~ 7 5, 8 ~ 9 10
Examples: 1.21=1.20, 1.26=1.25, 1.28=1.30
Special rounding 2
X
0 ~ 4 0, 5 ~ 9 10
Examples: 1.123=1.120, 1.525=1.530
Danish rounding
C
(set the amount tender restriction on page 22 also)
00~ 12 0, 13 ~ 37 25, 38 ~ 62 50,
63 ~ 87 75, 88 ~ 100 100
Examples: 1.11=1.00, 1.28=1.25, 1.39=1.50,
1.80=1.75, 1.99=2.00
Scandinavian rounding
N
00~ 24 0, 25 ~ 74 50, 75 ~ 99 100
Examples: 1.21=1.0, 1.30=1.50, 1.87=2.00
Australian rounding (only for tax rate 1)
M
0 ~ 2 0, 3 ~ 7 5, 8 ~ 9 10
Examples: 1.21=1.20, 1.26=1.25, 1.28=1.30
Tax system specifications for subtotal and total amounts
D
No specifications. ?
Specifies add-on rate tax. X
Specifies add-in rate tax (VAT). C
You can use either an add-on
rate tax or an add-in rate tax
(VAT), depending on the require-
ments in your area. You can
specify only one tax rate.
The normal rounding specifica-
tion tells the cash register how to
round tax amounts to the proper
number of decimal places.
The special rounding specifica-
tion and Danish rounding tell the
cash register how to round off
subtotals and totals so that their
least 2 digits are 00, 25, 50 and
75.
Note that the rounding specifi-
cation you program for your cash
register depends on the tax laws
of your country.
Co
?ZXBo
??"????p
????p
o
Select numbers
from list B
Select
number
from
list C
Select number
from list D
(To end the setting)
*
1
Program set code No. for tax
rate 2 is ?XXB.
Enter tax rate A
26
E
Part-2 CONVENIENT OPERATION
CAL
REG
OFF
RF
PGM
X
Z
Mode switch
PGM
1-9 To control tax status
printing
Co
?CXNo
???p
o
Select number
from list B
(To end the setting)
P3 appears in mode display
Program set code No.
Selections
Print tax total line (only for Australia).
Print tax symbol (only for Australia).
No ?
Yes Z
No X
Yes C
Yes
No
A
Selections
Print taxable amount.
Print taxable amount and tax amount for Add-in.
Yes ?
No Z
Yes X
No C
Yes
No
B
Select number
from list A
Always 0
27
Part-2 CONVENIENT OPERATION
Part-2
E
DBL
DEL
DEPT
SHIFT
14
9
15
10
CASH AMT
TEND
SUB
TOTAL
11
6
12
7
13
8
1
2
3
4
5
789
456
123
0
ABC DEF
GHI JKL MNO
PQRS
TUV
WXYZ
1
2
3 4
5
6
7
8
1-10 To program de-
partment, PLU,
clerk name
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
PGM
In the PGM 2 mode, the keyboard becomes character setting keyboard illustrated
below after specifying a department, or a message.
1Double size key
Use this key to specify the next character to
a double sized character. You must press
this key before each double sized charac-
ter.
2Alphabet keys
Use these keys to input characters. Refer
to the next page to enter characters.
3Right arrow key
Use this key to input the character located
on the same alphabet key. This key is also
used for inputting a space.
4Delete key
Use this key to delete character just
entered.
5Department keys
Use this key to specify department.
6Department shift key
Use this key to shift department.
1-10-2 Programming
department
name
1-10-1 Character
keyboard
Xk
G ><VVVZZZCCCp
åS \VV<<+<p
k
Example
Department 1 7
Name DAIRY
H
BA
up to 8 (4 double sized) characters
P2 appears in mode display
DA I R Y refer to 1-10-4
(To end the setting)
H
BA refer to 1-10-4
Department 1
Department 7
7Program end key (k key)
Use this key to terminate character
programming.
8Character program key (p key)
Use this key to program the department /
message characters just entered before.
28
Part-2 CONVENIENT OPERATION
E
1-10-3 Programming
receipt message
Xk
Xu
XVV<NNBB++
CCCNNNXXp
k
P2 appears in mode display
T H A N K fix K space
(To end the setting)
YOU
refer to 1-10-4
Line No.
Example
Line (1 ~ 5) 2
Message THANK YOU
up to 24 (12 double sized) characters
29
Part-2 CONVENIENT OPERATION
Part-2
E
1-10-4 Alphabetical
order
Characters are assigned to each numeric key. You can enter A by pressing <
once, B twice, C three times
The following tables indicate character assignment and the depression numbers
of the key to enter the appropriate character.
:
A
B
C
a
b
c
8
A .01 B .02 C .03 a .04 b .05 c .06 8 .07
< key
Ä
Å
Æ
Á
Â
À
Ã
A .08 A .09 A .10 A .11 A .12 A .13 A .14
Ç
â
ä
à
å
æ
á
C .15 a .16 a .17 a .18 a .19 a .20 a .21
ã
ç
returns to the beginning
a .22 c .23
:D
E
F
d
e
f
9
D .01 E .02 F .03 d .04 e .05 f .06 9 .07
> key
É
Ê
Ë
È
é
D .08 E .09 E .10 E .11 E .12 d .13 e .14
ê
ë
è
ƒ
returns to the beginning
e .15 e .16 e .17 f .18
:
G
H
I
g
h
i
4
G .01 H .02 I .03 g .04 h .05 i .06 4 .07
V key
Í
Î
Ï
Ì
ï
î
ì
I .08 I .09 I .10 I .11 I .12 i .13 i .14
í
ı
returns to the beginning
i .15 i .16
:
J
K
L
j
k
l
5
J .01 K .02 L .03 j .04 k .05 l .06 5 .07
B key returns to the beginning
:
M
N
O
m
n
o
6
M .01 N .02 O .03 m .04 n .05 o .06 6 .07
N key
Ñ
Ö
Ø
Ó
Ô
Ò
Õ
N .08 O .09 O .10 O .11 O .12 O .13 O .14
ñ
ô
ö
ò
ø
ó
õ
n .15 o .16 o .17 o .18 o o .19 o .20 o .21
returns to the beginning
A, B, C,
a, b, c,
8,
D, E, F,
d, e, f,
9,
G, H, I,
g, h, i,
4,
J, K, L,
j, k, l,
5,
M, N, O,
m, n, o,
6,
30
Part-2 CONVENIENT OPERATION
E
Cf.
A
B
A .01 B .02
Printing character
Indication of the above character
:
P
Q
R
S
p
q
r
P .01 Q .02 R .03 S .04 p .05 q .06 r .07
Z key
s
1
ß
returns to the beginning
s .08 1 .09 P .10 p .11 s .12
:
T
U
V
t
u
v
2
T .01 U .02 V .03 t .04 u .05 v .06 2 .07
X key
Ü
Ú
Û
Ù
ü
û
ù
U .08 U .09 U .10 U .11 u .12 u .13 u .14
ú
µ
returns to the beginning
u .15 u .16
:
W
X
Y
Z
w
x
y
W .01 X .02 Y .03 Z .04 w .05 x .06 y .07
C key
z
3
ÿ
returns to the beginning
z .08 3 .09 Y .10 y .11 y .12
:
0
returns to the beginning
? key 0 .01
:
7
@
-
/
:
!
?
7 .01 @ .02 - .03 / .04 : .05 ! .06 ? .07
M key
~
(
)
*
#
+
,
~ .08 ( .09 ) .10 * .11 # .12 + .13 , .14
^
;
<
=
>
$
¥
^ .15 ; .16 < .17 = .18 > .19 $ .20 ¥ .21
%
&
[
]
'
{
|
% .22 & .23 [ .24 ] .25 ' .26 { .27 | .28
}
"
.
\
_
'
} .29 .30 " .31 . .32 \ .33 _ .34 ' .35
£
¿
¡
§
space
£ .36 .37 ¿ .38 ¡ .39 .40 § .41 .42
returns to the beginning
P, Q , R, S ,
p, q, r, s,
1,
T, U, V,
t, u, v,
2,
W, X, Y, Z,
w, x, y, z,
3,
0
7,
Symbols,
31
Part-2 CONVENIENT OPERATION
Part-2
E
1-11 Printing to
read all
preset data
p
Printout
Operation
PGM1••••••••••••••••••••
DEPT01 T1 @1•00
000
DEPT02 @10.00
000
DEPT15 @5.00
000
- T1
%- T1 12.34%
00
EURO ™1.29739
0122 22
0522 1020
0622 0000
1022 0
0326 202
2422 22
0125
0.0000 %
5003
0000
0225
5.2500 %
5003
0000
01
02
YOUR RECEIPT
03
TAXABLE SUPPLY
—— Read Symbol
—— Dept. name/Tax status/Unit price
—— Normal dept./Digit limit/Single item
—— Minus/Tax status
—— Percent/Tax status/Rate
—— Fraction/Key attribution
—— Euro conversion rate
—— Date, Add mode control (fixed)
—— Print control
—— General control
—— Calculation control
—— Tax control
—— Euro program
—— Tax table 1
—— Tax table 2
—— Receipt message
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
PGM
32
E
2-3 Check sales
Example:
Unit Price $35.00
Quantity 2
Dept. 4
CB??F
F
o
ç
2-1 Registration using
preset price for de-
partments.
2. Various operations
Mode Switch
CAL
REG
OFF
RF
PGM
X
Z
REG
Part-2 CONVENIENT OPERATION
G
S
S
V∫D
o
B???p
Example
(Programming: See page 19)
Printout
Operation
$50.00
Unit Price $1.00 $2.20 $11.00
Quantity 1 2 4
Depts. 1 2 3
Amount
tendered
Example 1:
2-2 Single-Item Sales
(Programming: See page 20)
B? G
Status Single item sale
Unit Price $0.50
Quantity 1
Dept. 1
Example 2:
Single-item sale cannot be finalized if an item is registered previously.
Z??S
B?G
o
p
Status Normal Single item sale
Unit Price $1.00 $0.50
Quantity 1 1
Dept. 2 1
DEPT02 •1.00
DEPT01 •0.50
CASH
1
.
50
DEPT01 •0.50
CASH
0
.
50
DEPT01 •1.00
DEPT02 •2.20
DEPT02 •2.20
4 X @11.00
DEPT03 •44.00
TOTAL
49
.
40
CASH •50.00
CHANGE •0.60
——Cash sales
——Cash sales
DEPT04 •35.00
DEPT04 •35.00
CHECK
70
.
00
—— Check sales
Part-2
33
E
Z??G
X??S
k
B??p
|
Printout
Operation
Part-2 CONVENIENT OPERATION
2-4 Split cash/
check sales
Mode switch
2-6 Refund
CAL
REG
OFF
RF
PGM
X
Z
RF
Printout
Operation
Z??S
X??D
o
p
After you finish RF mode operation, be sure to return the mode switch
to the REG (register) setting.
Example
Unit Price $1.00 $2.00
Quantity 1 1
Dept. 2 3
C???S
XB??D
o
X???p
ç
DEPT02 •30.00
DEPT03 •25.00
TOTAL
55
.
00
CASH •20.00
CHARGE •35.00
RF 07-19-2003 13:55
0040
DEPT02 •1.00
DEPT03 •2.00
CASH
3
.
00
Refund mode symbol
Unit price $1.00 $2.00
Quantity 1 1
Depts. 1 2
Cash amount
tendered
$5.00
Example
2-5 Post receipt
issuance
You can issue a post receipt after finalizing a transaction by pressing |.
Note that all of the following condition must be satisfied:
Print receipt option is selected.
The receipt issuance status must be OFF.
The transaction must be finalized in the REG/RF mode using p, u or ç.
(Receipt is not issued.)
DEPT01 •1.00
DEPT02 •2.00
TOTAL
3
.
00
CASH •5.00
CHANGE •2.00
CASH
3
.
00
If the transaction contains more than 20 lines (including receipt header), then the total formatted post receipt is issued.
Note:
You can issue only one post receipt per transaction.
Example:
Unit Price $30.00 $25.00
Quantity 1 1
Depts. 2 3
Cash amount
$20.00
tendered
Check $35.00
(Post receipt)
(Total formatted post receipt)
(Receipt is issued.)
34
E
13-5#
08-01-04
~00
2-7-5 Reduction on
subtotal
Example:
Amount due reduced by $0.50.
Z??G
X??F
o
B?g
p
Printout
Operation
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
REG
2-7 Other registrations
2-7-1 Reading the time and
date
Flashes per second
Part-2 CONVENIENT OPERATION
Hour/Minute
Display
Operation
y
2-7-2 Paidout from cash
in drawer
Z???;
Printout
Operation
2-7-3 Cash received
on account
Printout
Operation
Printout
Operation
2-7-4 Registering
identification
numbers
A reference number or ID number of up to 8 digits can be registered prior to any transaction.
Day/Month/Year
N?? .
B?G
ZXCV
BNM<n
p
RC •6.00
PD •10.00
—— Paid out amount
DEPT01 •0.50
# 12345678
CASH
0
.
50
—— Reference No. or ID No.
—— Received on account amount
DEPT01 •1.00
DEPT04 •2.00
- -0.50
CASH
2
.
50
Part-2
35
E
Part-2 CONVENIENT OPERATION
Z??G
x
X??S
C??G
o
Mx
p
2-7-6 Premium/
Discount
2.5% premium/discount
(programmed to x key)
applied to first item.
7% premium/discount applied
to transaction total.
For programming the x key
as percent minus or percent
plus, see page 21.
For programming percent rate,
see page 19.
—— Premium rate
—— Premium amount
—— Subtotal
—— Premium rate
—— Premium amount
2-8 About the daylight saving time
It is possible to set the internal clock forward/backward by 1~9 hour(s)
for the daylight saving time.
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
REG
Operation Display
Forward by 1 hour
Backward by 1 hour
*
Z
y
J
*
Z
y
*Put X~>, in case of set the clock by 2~9 hours.
(blinking)
(blinking)
(blinking)
Set forward by 1 hour.
Set backward by 1 hour.
12-3$
12-3$
13-3$
~00
12-3$
12-3$
12-3$
11-3$
~00
DEPT01 •1.00
2.5%
%+ •0.03
DEPT02 •2.00
DEPT01 •3.00
ST •6.03
7%
%+ •0.42
CASH
6
.
45
DEPT01 •1.00
2.5%
%- -0.03
DEPT02 •2.00
DEPT01 •3.00
ST •5.97
7%
%- -0.42
CASH
5
.
55
—— Discount rate
—— Discount amount
—— Subtotal
—— Discount rate
—— Discount amount
Premium
Discount
36
E
t
BqZ t
BqCwX p
XCwBNeM< p
ZB??eZX x
CALCULATOR FUNCTION
Part 3
(Cancels item entered.)
(Miss operation)
1-1 Calculation
examples
1. Calculator
Mode
While registering at REG mode, you can switch to CAL
mode and then return to REG mode to resume the
registration.
Mode switch
CAL
REG
OFF
RF
PGM
X
Z
CAL
Operation
Display
5 + 3 2 =
(23 56) × 78 =
12% on 1500
1-2 Memory recall
CAL
REG
OFF
RF
PGM
X
Z
REG
Mode Switch
Recalls the current amount onto the display.
during registration: current subtotal
registration has been completed: the last amount
Memory recall
/rCp
Operation
Display
On CAL mode
Example:
Divide the current subtotal $30.00
at REG mode by 3 (to divide the bill
between 3 people).
On REG mode
Recalls the current result by pressing p key at CAL mode on the display.
Operation
Printout
/p
/p
/p
Example:
Recall the current result at CAL mode
during registration, and register the
cash amount due for each person.
Memory recall
DEPT01 •10.00
DEPT02 •20.00
TOTAL
30
.
00
CASH •10.00
CASH •10.00
CASH •10.00
CHANGE •0.00
0~
&
-257$
18~
1~
Part-3
37
E
No ?
Yes Z
No X
Yes C
No V
Yes B
No N
Yes M
Co
Z?XXo
?p
o
Mode Switch
CAL
REG
OFF
RF
PGM
X
Z
PGM
Part-3 CALCULATOR FUNCTION
1-3 Setting for calculator op-
eration
P3 appears in mode display
Select a number from list A.
(To end the setting)
Selections
A
Program code No.
Open drawer whenever p is pressed.*
* Drawer does not open during registration procedures even
if you press p by turning the mode switch to CAL
position.
Open drawer whenever n is pressed.
Print No. of Equal key operations on
General Control X and Z reports.
Yes
No
Yes
No
Yes
No
38
E
1. Troubleshooting
USEFUL INFORMATION
Part 4
Symptom/Problem
Most common causes
Solutions
1 E01 appears on the display.
2 E10 appears on the display.
3 No date or time on receipt.
Paper is not advancing enough.
4 Key wont turn to Z, X, PGM and RF modes.
5 Drawer opens up after ringing up only one
time.
6 Not clearing totals at end of day after taking
report.
7 Programming is lost whenever register is
unplugged or there is a power outage.
8 Register is inoperative.
Cant get money out of drawer.
Changing modes without completing transaction.
Printer is not closed steadily.
No paper
Printer is programmed as a journal.
Using OP key.
Department is programmed as a single item dept.
Using X mode to take out reports.
Bad or no batteries.
No power.
Return key to where it stops buzzing and
press p.
Close the printer steadily.
Replace new paper roll.
Program printer to print receipts.
Use the PGM key.
Program the dept. as a normal dept.
Use Z mode to take out reports.
Put in new batteries.
Pull lever underneath register at rear.
When the cash drawer does not open!
In case of power failure or the machine is in malfunction, the cash drawer does not open automati-
cally. Even in these cases, you can open the cash drawer by pulling drawer release lever (see below).
Important!
The drawer will not open, if it is locked with a drawer lock key.
If there is enough paper installed, open the printer and set the platen arm again.
Part-4
39
E
2. Specifications
Input method:
Entry: 10-key system; Buffer memory 16 keys (2-key roll over)
Display (Digitron): Amount 8 digits (zero suppression); Department No.; No. of repeats; TOTAL; CHANGE
Printer:
Receipt: 24 digits
(or journal) Automatic paper roll winding (journal)
Paper roll: 58 mm × 80 mm (Max.)
Calculations:
Entry 8 digits; Registration 7 digits; Total 8 digits
Calculator function:
8 digits; Arithmetic calculations; Percent calculations
Memory protection batteries:
The effective service life of the memory protection batteries (3 UM-3, R6P (SUM-3) or LR6 (AM-3) type batteries) is
approximately one year from installation into the machine.
Power source/Power consumption:
See the rating plate.
Operating temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 10 to 90%
Dimensions/Weight: 330 mm (W)× 360 mm (D)× 197 mm (H) with S drawer
4 kg with S drawer
410 mm (W)× 450 mm (D)× 240 mm (H) with M drawer
9 kg with M drawer
Specifications and design are subject to change without notice.
Casio Electronics Co., Ltd.
Unit 6, 1000 North Circular Road
London NW2 7JD, U.K.
Please keep all information for future reference.
The main plug on this equipment must be used to disconnect mains power.
Please ensure that the socket outlet is installed near the equipment and shall be easily
accessible.
TE-M80*E
MO0306-A Printed in Indonesia
Printed on recycled paper.
CASIO COMPUTER CO., LTD.
6-2, Hon-machi 1-chome
Shibuya-ku, Tokyo 151-8543, Japan
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio TE-M80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio TE-M80 in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio TE-M80

Casio TE-M80 User Manual - German - 40 pages

Casio TE-M80 User Manual - Dutch - 37 pages

Casio TE-M80 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info