Using the Sequencer
The following procedure contains only the most basic steps
for realtime recording. For other techniques you can use
during this procedure, see “Other System Track Realtime
Recording Techniques” on page E-58.
1. Press the SEQUENCER button.
This causes the button’s indicator lamp to light,
indicating that sequencer is turned on.
2. Select the song area to which you want to
record.
Use [+]/[–] buttons or the selector dial to select a
song area number in the range of 1 to 10.
After a few seconds, the display changes to the
play standby. You can also display the play
standby by pressing the EXIT/NO button.
3. Press the SEQUENCER button to display the
main sequencer menu.
Use the [ ]/[ ] buttons to select the setting you
want.
4. Specify the time signature and make any
metronome settings you want to use while
recording.
Use “Metronome Setting 5 : “Metro”” in the
Setting Mode on page E-63 to make metronome
settings.
After you select a setting, press the SEQUENCER
button or the EXIT/NO button to return to the
play standby screen.
5. Make the piano control panel settings you want
to use when you start your recording.
Select the tone, rhythm, and auto accompaniment
mode using the same procedures as those for
normal keyboard play. “Other System Track
Realtime Recording Techniques” on page E-58
also contains related information about these
settings.
See “System Track Data” on page E-54 for
information about what parameters you can set
prior to recording.
6. If you want to change mixer parameter settings,
hold down the FUNCTION button and press
PART/(MIXER) button and then configure the
settings you want.
You can use the mixer to change the parameters
of auto accompaniment and melody parts.
After making the settings you want, press the
EXIT/NO button to return to the recording
screen.
7. Press RECORD button to enter the Realtime
Record Mode.
The button’s indicator lamp flashes and the
sequencer goes into system track record standby.
8. Play something on the keyboard to start actual
recording.
1
Current measure and beat numbers
If you want to input rests (blank spaces) at the
beginning of a song, press the START/STOP
button to start recording, and then input as many
rests as you want. Next, play what you want on
the keyboard.
During recording, the metronome sounds (but is
not recorded) according to the settings you made
in step 4.
9. Play what you want on the keyboard.
Auto accompaniment chord changes, as well as
pedal and other operations are also recorded.
See “System Track Data” on page E-54 for more
information about the type of data that is
recorded.
10. After you are finished playing what you want,
press the START/STOP button to stop
recording and change to the sequencer’s
playback screen.
Pressing the START/STOP button at this time
plays back what you just recorded. See “Playing
Back from Sequencer Memory” on page E-60 for
more information about playback.
Realtime Recording
Realtime Recording to the System Track
426-E-059A
PL40NE01-1.book 57 ページ 2002年7月23日 火曜日 午後6時52
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio PL-40R at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio PL-40R in the language / languages: English as an attachment in your email.

The manual is 3,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio PL-40R

Casio PL-40R User Manual - English - 32 pages

Casio PL-40R User Manual - English - 10 pages

Casio PL-40R User Manual - English - 14 pages

Casio PL-40R User Manual - English - 34 pages

Casio PL-40R User Manual - German - 32 pages

Casio PL-40R User Manual - German - 10 pages

Casio PL-40R User Manual - German - 14 pages

Casio PL-40R User Manual - German - 50 pages

Casio PL-40R User Manual - German - 34 pages

Casio PL-40R User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info