Activity: SetupActivity: Setup
2-13-1
í Equipment
Stand
Voltaic Battery (Zinc Plate, Copper Plate, Dilute Sulfuric Acid Solution, Cistern)
Flashlight Bulb Hydrogen Peroxide Pipette with a bulb
Voltage Measurement Setup (EA-200, graphic scientific calculator, data communication
cable, voltage probe)
í Setting Up
u Taking care that the two electrodes do not become shorted, setup the equipment as
shown in the illustration.
This activity investigates the changes in the electromotive force of a voltaic battery over
time.
A voltaic battery is made of a zinc (Zn) plate and a copper (Cu) plate immersed in a dilute
solution of sulfuric acid (H
2
SO
4
). Employing the difference in the ionization tendencies
between the two metals, the zinc plate is the negative electrode (cathode), while the copper
plate is the positive electrode (anode).
Ionization tendency is the tendency of metal to release electrons, which become positively
charged ions. As shown below, zinc and copper are on opposite sides of the hydrogen
molecule.
K Ca Na Mg Al Zn Fe Ni Sn Pb (H
2
) Cu Hg Ag Pt Au
Exposing zinc, which has a relatively strong ionization tendency, to the hydrogen ions in a
dilute sulfuric acid solution, causes the zinc to dissolve and release electrons, creating a
minus charge. When the battery is connected to a circuit, the released electrons flow
through the circuit to become electric current, and collect on the copper plate, which has a
relatively weak ionization tendency and is not dissolving. The electrons on the surface of the
copper plate are consumed when they attach to hydrogen ions in the dilute sulfuric acid
solution and give off hydrogen gas. As the electrons on the copper plate are consumed, the
zinc plate releases more electrons, which allows the flow of current to continue. The
reaction that occurs at the two electrodes at this time is represented by the chemical
expression shown below.
Zn Zn
2+
+ 2e
(Negative Electrode Reaction)
2H
+
+ 2e
H
2
(Positive Electrode Reaction)
It should be noted here that should too much hydrogen gas foam build up on the copper
plate surface, a phenomenon called “polarization” can cause the hydrogen gas to start to
return to hydrogen ions. Allowing polarization to continue will lead to deterioration of the
electromotive force of the battery. If this happens, hydrogen peroxide can be added to the
area around the copper plate, which reacts with the hydrogen gas and reduces the amount
of foam present. This, in turn, restores the electromotive force of the battery. Repeating this
measure when required will theoretically allow the battery to operate properly until the zinc
plate is completely dissolved. In actual practice, a voltaic battery will reach the end of its
useful life before then.
Electromotive Force of a Battery
Theory
1 Dilute Sulfuric Acid Solution
2 Flashlight Bulb
3 Negative Electrode (Zinc Plate)
4 Positive Electrode (Copper Plate)
1 Stand
2 Cistern
3 Dilute Sulfuric Acid Solution
4 Zinc Plate
5 Copper Plate
6 Negative Electrode
7 Positive Electrode
8 Flashlight Bulb
9 Voltage Probe (CH1)
0 EA-200
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio EA200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio EA200 in the language / languages: English as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info