4
Humidity Measurements
The humidity display shows “LO” for humidity below 10% and “HI” for humidity above 90%.
Whenever the current temperature is outside the range of 0°C to 49.9°C, the humidity display will show “– –”.
Daily High Temperature/Humidity, Low Temperature/Humidity Memory
The clock remembers the highest and lowest temperature and humidity readings for the current 24-hour day.
Each press of the MAX/MIN button (
8
) cycles between screens as illustrated below.
Daily high and low temperature/humidity memory contents are cleared each day at midnight.
Changing the Temperature/Humidity Display Screen
Press of the MAX/MIN button (
8
). Each press cycles between screens as shown below.
Low temperature and humidity High temperature and humidity
MAX/MIN button (
8
)
Current temperature and humidity
MAX/MIN button
(
8
)
MAX/MIN button
(
8
)
Turning On Temperature/Humidity Screen Auto Cycling
Hold down the MAX/MIN button (
8
) for about one second. This will turn on temperature/humidity screen auto
cycling, which causes the screen contents to cycle from one screen to the next at regular intervals.
Low temperature and humidity High temperature and humidity
Current temperature and humidity
To turn off temperature/humidity screen auto cycling, press the MAX/MIN button (
8
).
BATTERY REPLACEMENT
Replace batteries whenever the display of the clock becomes dim and diffi cult to read.
1. Open the battery compartment cover as shown in the illustration.
2. Remove all of the old batteries.
3. Load a full set of new batteries. Make sure that their positive (+) and negative (–) ends face in the correct
directions. If you load batteries incorrectly, they can burst and damage the clock.
4. Press the RESET button (
6
).
5. Replace the battery compartment cover.
Battery precautions
Keep batteries out of the reach of small children. If a battery is accidentally swallowed, contact your physician
immediately.
Be sure to load the batteries with their positive (+) and negative (–) ends facing correctly.
Never mix old and new batteries, or batteries of different brands.
Never charge the batteries.
Should batteries ever leak while in the clock, wipe out the fl uid with a cloth, taking care not to let any get onto
your skin.
Replace the batteries at least once a year, even if the current batteries are working properly.
The batteries that come with the clock lose some of their power during transport and storage.
SPECIFICATIONS
Accuracy at Normal Temperature: ±60 seconds a month
Calendar System: Auto-calendar pre-programmed from the year 2000 to 2099
Alarm: Daily Alarm, Snooze Alarm (7 repeats)
Thermometer Functions: Measuring range: –19.9°C to 49.9°C (–3.8°F to 121.8°F)
Though temperature readings are displayed up to 0°C (32°F) and greater than 41°C (105°F), note that such
readings are actually outside the guaranteed temperature range of this clock.
High/Low Temperature Memory, Celsius (°C)/Fahrenheit (°F) switching
Temperature Sensor Precision: ±2°C (±4°F) in range of 0°C to 40°C (32°F to 104°F)
Hygrometer Function: Measuring range: 10% to 90%, when temperature is 0°C to 40°C (32°F to 104°F)
High/Low Humidity Memory
Humidity Sensor Precision: ±10%, when temperature is 5°C to 40°C (41°F to 104°F)
Other: LED light, ALL NIGHT LIGHT, 12/24-hour timekeeping
Battery: Two AA size batteries (Type: LR6)
Battery Life: Approximately 1 year
1 minute alarm operation per day
5 seconds light operation per day
8 hours ALL NIGHT LIGHT operation per day
Operating Temperature: 0°C to 40°C (32°F to 104°F)
Specifi cations are subject to change without notice.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio DQ-982N at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio DQ-982N in the language / languages: English as an attachment in your email.

The manual is 0,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info