pp ........ Program Number = 00H to 7FH
Send
Program Change messages are sent when you select a tone on the
instrument.
Pitch Bend Change
Format
Byte 1 Byte 2
CnH ppH
n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16)
ll .......... Pitch Bend Change LSB = 00H to 7FH
mm ..... Pitch Bend Change MSB = 00H to 7FH
Byte 1 Byte 2 Byte 3
EnH llH mmH
Filter Cut Off Frequency
NRPN MSB = 01H
NRPN LSB = 20H
Data Entry MSB = mmH
mm ..... Filter Cut Off Frequency = 00H to 40H to 7FH (-64 to 0 to
+63)
Recognition
When the instrument receives this message, the preset Filter Cut
off Frequency value for the tone is changed to the value that
corresponds to the data entry MSB of the received message. There
is no change when the value of the data entry MSB is 40H(0).
Filter Resonance
NRPN MSB = 01H
NRPN LSB = 21H
Data Entry MSB = mmH
mm ..... Resonance= 00H to 40H to 7FH (-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset Filter
Resonance value for the tone is changed to the value that
corresponds to the data entry MSB of the received message. There
is no change when the value of the data entry MSB is 40H(0).
Filter/AMP Envelope Attack Time
NRPN MSB = 01H
NRPN LSB = 63H
Data Entry MSB = mmH
mm ..... Filter/AMP Envelope Attack Time = 00H to 40H to 7FH
(-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset Filter/AMP
Envelope Attack Time value for the tone is changed to the value
that corresponds to the data entry MSB of the received message.
There is no change when the value of the data entry MSB is 40H(0).
Filter/AMP Envelope Decay Time
NRPN MSB = 01H
NRPN LSB = 64H
Data Entry MSB = mmH
mm ..... Filter/AMP Envelope Decay Time = 00H to 40H to 7FH
(-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset Filter/AMP
Envelope Decay Time value for the tone is changed to the value
that corresponds to the data entry MSB of the received message.
There is no change when the value of the data entry MSB is 40H(0).
Filter/AMP Envelope Release Time
NRPN MSB = 01H
NRPN LSB = 66H
Data Entry MSB = mmH
mm ..... Filter/AMP Envelope Release Time = 00H to 40H to 7FH
(-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset Filter/AMP
Envelope Release Time value for the tone is changed to the value
that corresponds to the data entry MSB of the received message.
There is no change when the value of the data entry MSB is 40H(0).
RPN (Registered Parameter Numbers)
Format
Byte 1 Byte 2 Byte 3
BnH 65H qmH (MSB)
BnH 64H qlH (LSB)
n .......... Voice Channel Number = 0H to FH (Ch1 to Ch16)
qm ....... MSB of RPN
ql ......... LSB of RPN
Recognition
RPN messages not defined by the instrument can also be
received, but subsequent data entry values after undefined RPN
messages are ignored.
After the MSB and LSB of an RPN are received and the applicable
control parameters settings are made, the value is set by receipt
of the MSB of the subsequent data entry. The data entry LSB is
ignored.
Send
An RPN is sent whenever an operation that changes the parameter
assigned to the RPN is performed.
Pitch Bend Sensitivity
RPN MSB = 00H
RPN LSB = 00H
Data Entry MSB = mmH
mm ..... Pitch Bend Sensitivity = 00H to 18H (0 to 24 semitones)
Recognition
The data entry LSB is always ignored.
Master Fine Tuning
RPN MSB = 00H
RPN LSB = 01H
Data Entry MSB = mmH
Data Entry LSB = llH
mm ll .......... Master Fine Tuning = 00 00H to 40H 00H to 7FH 7FH
(-100 to 0 to +99.99 cents)
Master Coarse Tuning
RPN MSB = 00H
RPN LSB = 02H
Data Entry MSB = mmH
mm ..... Master Coarse Tuning = 28H to 40H to 58H (-24 to 0 to +24
semitones)
Recognition
The data entry LSB is always ignored.
RPN Null
RPN MSB = 7FH
RPN LSB = 7FH
Recognition
Once an RPN Null is sent, all received data entry MSBs and LSBs
are ignored until another RPN message other than RPN Null or an
NRPN message is received.
Program Change
Format
428A-E-090A
AP38_e_MIDI Data.p65 02.6.12, 15:566
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio AP38 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio AP38 in the language / languages: English as an attachment in your email.

The manual is 1,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio AP38

Casio AP38 User Manual - German - 56 pages

Casio AP38 User Manual - Dutch - 20 pages

Casio AP38 User Manual - Spanish - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info