27155
39
Zoom out
Zoom in
Previous page
1/50
Next page
A-5
Filter/AMP Envelope Release Time
NRPN MSB = 01H
NRPN LSB = 66H
Data Entry MSB = mmH
mm .. Filter/AMP Envelope Release Time = 00H to 40H
to 7FH (-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset
Filter/AMP Envelope Release Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when
the value of the data entry MSB is 40H(0).
427B-E-069B
Filter Cut Off Frequency
NRPN MSB = 01H
NRPN LSB = 20H
Data Entry MSB = mmH
mm .. Cut Off Frequency = 00H to 40H to 7FH (-64 to 0 to
+63)
Recognition
When the instrument receives this message, the preset
Filter Cut off Frequency value for the tone is changed to
the value that corresponds to the data entry MSB of the
received message. There is no change when the value of
the data entry MSB is 40H(0).
Filter Resonance
NRPN MSB = 01H
NRPN LSB = 21H
Data Entry MSB = mmH
mm .. Filter Resonance= 00H to 40H to 7FH (-64 to 0 to
+63)
Recognition
When the instrument receives this message, the preset
Filter Resonance value for the tone is changed to the val-
ue that corresponds to the data entry MSB of the received
message. There is no change when the value of the data
entry MSB is 40H(0).
Filter/AMP Envelope Attack Time
NRPN MSB = 01H
NRPN LSB = 63H
Data Entry MSB = mmH
mm .. Filter/AMP Envelope Attack Time = 00H to 40H
to 7FH (-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset
Filter/AMP Envelope Attack Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when
the value of the data entry MSB is 40H(0).
Filter/AMP Envelope Decay Time
NRPN MSB = 01H
NRPN LSB = 64H
Data Entry MSB = mmH
mm .. Filter/AMP Envelope Decay Time = 00H to 40H
to 7FH (-64 to 0 to +63)
Recognition
When the instrument receives this message, the preset
Filter/AMP Envelope Decay Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when
the value of the data entry MSB is 40H(0).
Byte 1 Byte 2 Byte 3
BnH 65H qmH (MSB)
BnH 64H qlH (LSB)
The MSB and LSB of an RPN specify the parameter be-
ing controlled, while the specified parameters value is
set in accordance with the MSB of the subsequent data
entry.
See Pitch Bend Sensitivity through RPN Null for the
data entry MSB value range and other details.
Format
RPN (Registered Parameter Numbers)
On the instrument, RPNs are defined as settings for the fol-
lowing parameters.
NRPN MSB NRPN LSB Parameter
00H 00H Pitch Bend Sensitivity
00H 01H Master Fine Tuning
00H 02H Master Coarse Tuning
7FH 7FH RPN Null
n ....... Voice Channel Number = 0H to FH (Ch1 to Ch16)
qm ... MSB of RPN
ql ..... LSB of RPN
Recognition
RPN messages not defined by the instrument can also
be received, but subsequent data entry values after un-
defined RPN messages are ignored.
After the MSB and LSB of an RPN are received and the
applicable control parameters settings are made, the
value is set by receipt of the MSB of the subsequent
data entry. The data entry LSB is ignored.
Send
An RPN is sent whenever an operation that changes the
parameter assigned to the RPN is performed.
AP31/33_E_MIDI Data.p65 03.10.7, 11:00 AMPage 5 Adobe PageMaker 6.5J/PPC
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio AP31 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio AP31 in the language / languages: English as an attachment in your email.

The manual is 2,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio AP31

Casio AP31 User Manual - German - 48 pages

Casio AP31 User Manual - Dutch - 60 pages

Casio AP31 User Manual - Spanish - 50 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info