624852
15
Zoom out
Zoom in
Previous page
1/15
Next page
E-112
Altimeter:
Measurement range: –700 to 10,000 m (or –2,300 to 32,800 ft.) without reference altitude
Display range: –3,000 to 10,000 m (or –9,840 to 32,800 ft.)
Negative values can be caused by readings produced based on a reference altitude or due to
atmospheric conditions.
Measurement Unit: 1 m (or 5 ft.)
Current Altitude Data: Every second for the fi rst 3 minutes, followed by every 5 seconds for
approximately 1 hour (
0'05
); every second for the fi rst 3 minutes, followed by every 2 minutes for
approximately 12 hours (
2'00
)
Altitude Memory Data:
Manually saved records: 30 (altitude, date, time)
Auto saved values: One set of high altitude and its reading date and time, low altitude and its
reading date and time, total ascent and its save start date and time, total descent and its save
start date and time
Other: Reference altitude setting; Altitude differential (–100 to +100m/–1,000 to +1,000m); Altitude
auto measurement interval (
0'05
or
2'00
)
Barometer:
Measurement and display range:
260 to 1,100 hPa (or 7.65 to 32.45 inHg)
Display unit: 1 hPa (or 0.05 inHg)
Other: Calibration; Barometric pressure graph; Barometric pressure differential pointer; Barometric
pressure change indicator
Thermometer:
Measurement and display range: –10.0 to 60.0°C (or 14.0 to 140.0°F)
Display unit: 0.1°C (or 0.2°F)
Other: Calibration
E-113
Bearing Sensor Precision:
Direction: Within ±10°
Values are guaranteed for a temperature range of 10°C to 40°C (50°F to 104°F).
North indicated by second hand: Within ±2 segments
Pressure Sensor Precision:
Measurement accuracy: Within ±3hPa (0.1 inHg) (Altimeter accuracy: Within ± 75m (246 ft.))
Values are guaranteed for a temperature range of –10°C to 40°C (14°F to 104°F).
Precision is lessened by strong impact to either the watch or the sensor, and by temperature
extremes.
Temperature Sensor Precision:
±2°C (±3.6°F) in range of –10°C to 60°C (14.0°F to 140.0°F)
Stopwatch:
Measuring unit: 1/100 second
Measuring capacity: 23:59' 59.99"
Measuring modes: Elapsed time, split time, two fi nishes
Countdown Timer:
Measuring unit: 1 second
Countdown range: 60 minutes
Setting unit: 1 minute
Alarms:
5 Daily alarms; Hourly time signal
World Time:
29 cities (29 time zones), UTC (Universal Time Coordinated); Home City/World Time City
switching; one-touch UTC zone access
Other: Daylight Saving Time/Standard Time
Illumination:
LED light; Selectable illumination duration (approximately 1.5 seconds or 3 seconds); Auto
Light Switch (Full Auto Light operates only in the dark)
E-114
Other:
Battery power indicator; Power Saving; Button operation tone on/off; alarm test; auto hand position
adjustment; hand shift feature (to view digital info)
Power Supply:
Solar panel and one rechargeable battery
Approximate battery operating time: 6 months (from full charge to Level 4) under the following
conditions:
Light: 1.5 seconds/day
Beeper: 10 seconds/day
Direction readings: 20 times/month
Climbs: Once (approximately 1 hour of altitude readings)/month
Barometric pressure change indicator readings: Approximately 24 hours/month
Barometric pressure graph: Readings every 2 hours
Time calibration receive: 4 minutes/day
Display: 18 hours/day
Frequent use of illumination runs down the battery. Particular care is required when using the auto
light switch (page E-101).
L-1
L-2
City Code Table
City
Code
City
UTC Offset/
GMT Differential
PPG Pago Pago –11
HNL Honolulu –10
ANC Anchorage –9
LAX Los Angeles –8
DEN Denver –7
CHI Chicago –6
NYC New York –5
SCL Santiago –4
RIO Rio De Janeiro –3
RAI Praia –1
UTC
0
LON London
PAR Paris +1
ATH Athens +2
JED Jeddah +3
THR Tehran +3.5
DXB Dubai +4
City
Code
City
UTC Offset/
GMT Differential
KBL Kabul +4.5
KHI Karachi +5
DEL Delhi +5.5
KTM Kathmandu +5.75
DAC Dhaka +6
RGN Yangon +6.5
BKK Bangkok +7
HKG Hong Kong +8
TYO Tokyo +9
ADL Adelaide +9.5
SYD Sydney +10
NOU Noumea +11
WLG Wellington +12
Based on data as of December 2013.
The rules governing global times (GMT
differential and UTC offset) and summer time
are determined by each individual country.
Operation Guide 5365
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Casio 5365 - PRW-6000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Casio 5365 - PRW-6000 in the language / languages: English as an attachment in your email.

The manual is 1,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Casio 5365 - PRW-6000

Casio 5365 - PRW-6000 User Manual - German - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info