Operation
Water drainage
-During dehumidifying modes, remove the upper drain
plug from the back of the unit, install the drain connector
(5/8" universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of
the hose directly over the drain area in your basement
floor.
WAIT 3 MINUTES BEFORE RESUMING OPERATION
After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect the unit.
Operation will automatically start after 3 minutes.
POWER MANAGEMENT feature(on some models)
When the ambient temperature is lower than the setting
temperature for a period of time, the unit will be
automatically operate power management feature. The
compressor and fan motor stop. When the ambient
temperature is higher than the setting temperature, the unit
will be automatically quit the power management feature.
The compressor and (or) fan motor run.
NOTE: For unit with power management light, the light
will illuminate under this feature.
-During heating pump mode, remove the lower drain plug
from the back of the unit, install the drain connector(5/8"
universal female mender) with 3/4" hose(locally
purchased). For the models without drain connector, just
attach the drain hose to the hole. Place the open end of
the Hose adaptor directly over the drain area in your
basement floor.
NOTE: Make sure the hose is secure so there are no
leaks.Direct the hose toward the drain, making sure that
there are no kinks that will stop the warter flowing.Place
the end of the hose into the drain and make sure the end
of the hose is down to let the water flow smoothly.(See
Figs with . Do never let it up.(See Figs with ). When
the continuous drain hose is not used, ensure that the
corresponding drain plug and knob are installed firmly to
prevent leakage.
X
Maintenance
-Always unplug the unit before cleaning or servicing.
-DO NOT use flammable liquids or chemicals to clean the unit.
-DO NOT wash the unit under running water. Doing so
causes electrical danger.
-DO NOT operate the machine if the power supply was damaged
during cleaning. A damaged power cord must be replaced with a
new cord from the manufacturer.
Clean the Air Filter
Remove the air filter
Upper filter
(take out)
Remove the
screw,then
take the lower
filter out.
WARNING:
MODEL A
MODEL B
MODEL A
MODEL B
MODEL A
MODEL B
15
drain hose
adaptor
Continuous
drain hose
Remove the
lower drain plug
drain hose
adaptor
Continuous
drain hose
Remove the
lower drain plug
SCALE 0.500
Remove the
upper drain plug
Continuous
drain hose
Remove the
upper drain plug
Continuous
drain hose
Uper air filter
(take out)
Lower air filter
(take out)
SCALE 0.500
SCALE 0.500
SCALE 0.500
X
drain hose
adaptor
Press the power
cord buckle into
the rear cover.
drain hose
adaptor
delivery lift <1.8m
-When the water level of the bottom tray reaches a
predetermined level, the unit beeps 8 times, the digital
display area shows "P1" . At this time the air
conditioning/dehumidification process will
immediately stop. However, the fan motor
will continue to operate(this is normal).
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away. Reinstall the bottom
drain plug and restart the machine until
the "P1" symbol disappears. If the error repeats, call for
service. NOTE: Be sure to reinstall the bottom drain plug
firmly to prevent leakage before using the unit.
CAUTION
DO NOT operate the unit without filter because dirt
and lint will clog it and reduce performance.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 51QPD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 51QPD in the language / languages: English as an attachment in your email.

The manual is 4,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Carrier 51QPD

Carrier 51QPD User Manual - English - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info