717501
15
Zoom out
Zoom in
Previous page
1/18
Next page
INSTALLATION INSTRUCTIONS
Water drainage:
- During dehumidifying modes, remove the upper
drain plug from the back of the unit, install the drain
connector(5/8 universal female mender) with
3 4 hose(locally purchased). For the models
without drain connector, just attach the drain
hose to the hole. Place the open end of the
hose directly over the drain area in your basement
floor. Please refer to Fig.20a.
- During heating pump mode, remove the lower drain
plug from the back of the unit, install the drain
connector(5/8 universal female mender) with
3/4 hose(locally purchased). For the models
without drain connector, just attach the drain
hose to the hole. Place the open end of the
hose adaptor directly over the drain area in your
basement floor. Please refer to Fig.20b.
- When the water level of the bottom tray reaches
a predetermined level,
Carefully move the unit to a drain location,
remove the bottom drain plug and let the
water drain away(Fig.22). Reinstall the bottom
drain plug and restart the machine until the P1
symbol disappears. If the error repeats, call for
service.
the unit beeps 8 times,
the digital display area shows P1 . At this time
the air conditioning/dehumidification process will
immediately stop. However, the fan motor will
continue to operate(this is normal).
Remove the
upper drain plug
Continuous
drain hose
Fig.20a
Fig.20b
Fig.22
NOTE: Be sure to reinstall the bottom drain plug
before using the unit.
Remove the
lower drain plug
Continuous
drain hose
drain hose
adaptor
NOTE:
Make sure the hose is secure so there are
no leaks.Direct the hose toward the drain,making
sure that there are no kinks that will stop the warter
flowing.Place the end of the hose into the drain and
make sure the end of the hose is down to let the
water flow smoothly.(See Fig.20a,20b,21a).Do
never let it up.(See Fig.21b).
Fig.21a Fig.21b
drain hose
adaptor
drain hose
adaptor
delivery l
ift <
1.
8
m
13
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 51QPD at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 51QPD in the language / languages: English as an attachment in your email.

The manual is 3,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Carrier 51QPD

Carrier 51QPD Installation Guide - English - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info