Operation tips
The following events may occur during normal operation.
1. Protection of the air conditioner.
Compressor protection
The compressor can't restart for 3 minutes after it stops.
Anti-cold air (Cooling and heating models only).
The unit is designed not to blow cold air on HEAT mode,
when the indoor heat exchanger is in one of the following
three situations and the set temperature has not been
reached.
A) When heating has just starting.
B) Defrosting.
C) Low temperature heating.
• The indoor or outdoor fan stop running when defrosting
(Cooling and heating models only).
Defrosting (Cooling and heating models only)
• Frost may be generated on the outdoor unit during heat cycle
when outdoor temperature is low and humidity is high
resulting in lower heating efficiency of the air conditioner.
• During this condition air conditioner will stop heating
operation and start defrosting automatically.
• The time to defrost may vary from 4 to 10 minutes according
to the outdoor temperature and the amount of frost buildup on
the outdoor unit.
2. A white mist coming out from the indoor unit
• A white mist may generate due to a large temperature
difference between air inlet and air outlet on COOL mode in
an indoor environment that has a high relative humidity.
A white mist may generate due to moisture generated from
defrosting process when the air conditioner restarts in HEAT
mode operation after defrosting.
3. Low noise of the air conditioner
• You may hear a low hissing sound when the compressor is
running or has just stopped running.
This sound is the sound of the refrigerant flowing or coming to
a stop.
• You can also hear a low "squeak" sound when the
compressor is running or has just stopped running. This is
caused by heat expansion and cold contraction of
the plastic parts in the unit when the temperature is changing.
• A noise may be heard due to louver restoring to its original
position when power is first turned on.
4. Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not
been used for a long time or during first use of the unit.
5. A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated
from building material, from furniture, or smoke.
6. The air conditioner turns to FAN only mode from COOL or
HEAT (For cooling and heating models only) mode.
When indoor temperature reaches the temperature setting on
air conditioner, the compressor will stop automatically, and the
air conditioner turns to FAN only mode.
The compressor will start again when the indoor temperature
rises on COOL mode or falls on HEAT mode (For cooling and
heating models only) to the set point.
7. Dripping water may generate on the surface of the indoor
unit when cooling in a high relatively humidity (relative
humidity higher than 80%).
Adjust the horizontal louver to the maximum air outlet position
and select HIGH fan speed.
8. Heating mode
(For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and
releases it via the indoor unit during heating operation. When
the outdoor temperature falls, heat drawn in by the air
conditioner decreases accordingly.
At the same time, heat loading of the air conditioner increases
due to larger difference between indoor and outdoor temperatu-
re. If a comfortable temperature can't be achieved by the air
conditioner, we suggest you use a supplementary heating
device.
9. Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power
restores, the OPERATION indicator on the indoor unit starts
flashing. To restart the operation, push the ON/OFF button on
the remote controller.
For the unit with Auto-restart feature, when the power restores,
the unit restarts automatically with all the previous settings
preserved by the memory function.
10.Lightning or a car wireless telephone operating nearby
may cause the unit to malfunction.
Disconnect the unit with power and then re-connect the unit
with power again.
Push the ON/OFF button on the remote controller to restart
operation.
42HQE009. / 012.
13


Need help? Post your question in this forum.

Forumrules
1

Forum

carrier-42hqe012-allegro-plus

Reset search

  • ??? µp??? ?a ß?? t??e?e???st???? ??a aircontision carrier alegro plus ;;;; Submitted on 12-8-2023 at 19:33

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 42hqe012 allegro plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 42hqe012 allegro plus in the language / languages: English as an attachment in your email.

The manual is 0,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info