481299
5
Zoom out
Zoom in
Previous page
1/9
Next page
3
Projection
15 mm or less
Anchor bolt
Clip anchor
(local parts)
5 mm dia. hole
Mounting screw
Ø4 x 25 R
7
Installation plate
(Keep horizontal direction.)
5 mm dia. hole
Clip anchor
(local parts)
Mounting screw
Ø4 x 25R
Anchor bolt
Projection
15 mm or less
INDOOR UNITINDOOR UNIT
Installation Place
A place which provides the spaces around the indoor unit as shown in the
diagram
• A place where there are no obstacles near the air inlet and outlet
• A place which allows easy installation of the piping to the outdoor unit
• A place which allows the front panel to be opened
The indoor unit shall be installed as top of the indoor unit comes to at least
2 m height. Also, it must be avoided to put anything on the top of the indoor
unit.
• Direct sunlight to the indoor unit’s wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF noise
sources.
(For details, see the owners manual.)
Remote control
A place where there are no obstacles such as a curtain that may block the
signal from the indoor unit
Do not install the remote control in a place exposed to direct sunlight or close
to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or stereo
equipment. (This is necessary to prevent image disturbances or noise inter-
ference.)
• The location of the remote control should be determined as shown below.
Cutting a Hole and Mounting
Installation Plate
NOTE
When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
Cutting a hole
When installing the refrigerant pipes from the rear
1. After determining the pipe hole position on the mounting plate (), drill the
pipe hole (Ø65 mm) at a slight downward slant to the outdoor side.
CAUTION
54 °
4
5°
5
7
°
(Side view) (Top view)
Indoor unit
Reception range
Remote
control
Remote
control
Reception
range
Indoor unit
65 mm
100 mm
80 100 180
42NQ012
The center of the pipe hole
is above the arrow.
Pipe hole
90 mm
66 mm
Ø
65
mm
42 mm
The center of the pipe hole is above the arrow.
Pipe hole
42NQ009
Mounting the installation plate
A
D
B
C
1
7
Anchor bolt holes
Hook
Hook
Hook
Pipe hole
Pipe hole
Installation
plate
Mounting screw
Weight
Indoor unit
Thread
2 m or more from oor
42NQ009
42NQ012
A 35 mm 62 mm
B 55.5 mm 82.5 mm
C 120 mm 170 mm
D 65 mm 85 mm
When the installation plate is directly mounted
on the wall
1. Securely t the installation plate onto the wall by screwing it in the upper and
lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use the
anchor bolt holes as illustrated in the below gure.
3. Install the installation plate horizontally in the wall.
CAUTION
Electrical Work
1. The supply voltage must be the same as the rated voltage of the air condi-
tioner.
2. Prepare the power source for exclusive use with the air conditioner.
NOTE
• Wire type : More than H07RN-F or 245 IEC66
Failure to rmly install the unit may result in personal injury and property
damage if the unit falls.
In case of block, brick, concrete or similar type walls, make 5 mm dia. holes
in the wall.
• Insert clip anchors for appropriate mounting screws 7.
NOTE
Secure four corners and lower parts of the installation plate with 4 to 6
mounting screws to install it.
CAUTION
NOTE
• Ensure all wiring is used within its electrical rating.
This appliance can be connected to the mains in either of the following
two ways.
(1) Connection to xed wiring:
A switch or circuit breaker which disconnects all poles and has a
contact separation of at least 3 mm must be incorporated in the xed
wiring. An approved circuit breaker or switches must be used.
(2) Connection with power supply plug:
Attach power supply plug with power cord and plug it into wall outlet.
An approved power supply cord and plug must be used.
CAUTION
Model 42NQ009 42NQ012
Power source 50Hz, 220 – 240 V Single phase
Maximum running current 7.5A 12A
Plug socket & fuse rating 16A
Power cord 1 mm
2
or more 1.5 mm
2
or more
When installing the installation plate with a mounting screw, do not use
the anchor bolt holes. Otherwise, the unit may fall down and result in
personal injury and property damage.
For the air conditioner that does not have power cord, connect a power
cord to it as mentioned below.
(1) Open the air inlet grille upward.
(2) Remove the two screws securing the front panel.
How to connect the power cord
1110251161-EN.indd 31110251161-EN.indd 3 12/28/07 6:10:49 PM12/28/07 6:10:49 PM
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 38NY009 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 38NY009 in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Carrier 38NY009

Carrier 38NY009 User Manual - English - 6 pages

Carrier 38NY009 User Manual - Dutch - 4 pages

Carrier 38NY009 User Manual - Spanish - 6 pages

Carrier 38NY009 User Manual - All languages - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info