481299
3
Zoom out
Zoom in
Previous page
1/6
Next page
TIMER OPERATION
10
Setting ON/OFF Timer
". Press ON or OFF.
2. Press SET : Set the timer.
3. Press CLR : Cancel the timer.
4. Press
START/STOP : Stop the air conditioner timer.
Note:
If you do not press the SET, ON or OFF button for 30 seconds, the timer
setting is cancelled.
AUTO RESTART OPERATION
11
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
". Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
OPERATION AND PERFORMANCE
13
". Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released
into the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This
is normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room Temperature
42NQ009, 012
42NQV009S, 012S
Heating -"0°C ~ 24°C Less than 28°C
Cooling "5°C ~ 43°C 2"°C ~ 32°C
Dry "5°C ~ 43°C "7°C ~ 32°C
The unit does not operate. Cooling is abnormally low.
The power main switch is turned
off.
The circuit breaker is activated to
cut off the power supply.
Stoppage of electric current
ON timer is set.
The Þ lters are blocked with dust.
The temperature has been set
improperly.
The windows or doors are opened.
The air inlet or outlet of the outdoor
unit is blocked.
The fan speed is too low.
The operation mode is FAN or
DRY.
TROUBLESHOOTING (CHECK POINT)
14
REMOTE CONTROL A-B SELECTION
15
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
". Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display.
4. Press [MODE] during pushing [CHK]. “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: ". Repeat above step to
reset Remote Control to
be A.
2. Remote Control A has
not “A” display.
3. Default setting of
Remote Control from
factory is A.
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the Þ lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit.
Indoor Unit and Remote Control
Clean the indoor unit and the remote control with a wet cloth when
needed.
No benzine, thinner, polishing powder or chemically-treated duster.
MAINTENANCE
12
MODE
AUTO
COOL
FAN
TEMP.
TEMP
AUTO
HEAT
DRY
B
B
EN
"""0250"28.indb 3 "2/22/07 "0:53:54 AM
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carrier 38NY009 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carrier 38NY009 in the language / languages: English, Spanish as an attachment in your email.

The manual is 0,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Carrier 38NY009

Carrier 38NY009 User Manual - English - 9 pages

Carrier 38NY009 User Manual - Dutch - 4 pages

Carrier 38NY009 User Manual - All languages - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info