789121
20
Zoom out
Zoom in
Previous page
1/40
Next page
20 • EN
The measurement is not reliable for:
Children under approx. 10 years of age;
Professional sporters and bodybuilders;
Pregnant women;
Persons with fever, undergoing dialysis, with symptoms of edema or osteoporosis;
Persons taking cardiovascular medication.
Persons taking vascodialating or vascoconstricting medications;
Persons with substantial anatomical deviations in the legs relative to their total height (leg length considerably shorter or
longer than usual).
Incorrect measurement
If the scale detects an error during measurement, this is indicated with Err.
Possible causes of errors Causes of error
The electrical resistance between the electrodes and
the soles of your feet is too high (e.g. with heavily
callused skin).
Repeat weighing barefoot. Slightly moisten the soles of your
feet if necessary. Remove the calluses on the soles of your feet if
necessary.
The fat percentage is outside the measurable range
(less than 5% or greater than 50%).
Repeat weighing barefoot. Slightly moisten the soles of your feet
if necessary.
The water percentage is outside the measurable
range (less than 10% or greater than 80%).
Repeat weighing barefoot. Slightly moisten the soles of your feet
if necessary.
The muscle and bone percentages are outside the
measurable range - age and gender related (less than
10% or greater than 80%).
Repeat weighing barefoot. Slightly moisten the soles of your feet
if necessary.
The maximum load-bearing capacity of 180 kg (397
lb) was exceeded [Err].
Only weigh the maximum permissible weight.
When only the body weight is shown, you are not
standing correctly on the scale.
Make sure your feet are placed on the measuring strips.
Cleaning & maintenance
The scale should be cleaned occasionally. Dirt and dust has a tendency to collect on the rubber electrodes. Always stand on
the scale barefoot or wearing socks as the rubber surfaces will quickly become dirty if you wear shoes. Use a damp cloth to
clean the scale. Do not use abrasive detergents and never immerse the scale in water.
Do not use aggressive solvents or cleaning agents!
Never immerse the scale in water or any other liquids.
Handle the scale with care, protect the scale from impact with hard object and do not drop it.
Your scale is fitted with a change battery indicator. If the scale is operating with batteries which are too weak, Lo appears
on the display and the scale will switch off automatically. In this case, the batteries must be exchanged (2 x AAA, 1,5V). If
necessary please use a small screwdriver to remove the batteries.
Batteries can contain toxins that are harmful to health and the environment. The used, completely drained standard and
rechargeable batteries must be disposed of in specially marked collection containers, at toxic waste collection points or
electrical product retailers. You are legally obligated to dispose of the batteries.
Note: Batteries containing pollutants are marked with the following symbols: Pb = Battery contains lead, Cd = Battery
contains cadmium, Hg = Battery containers mercury.
Recycling
This symbol means that this product should not be disposed of with regular household waste (2012/19/EU).
Observe the rules that apply in your country for the separated collection of electric and electronic products.
Correct disposal of the product prevents negative consequences for the environment and for public health.
The packaging material of this product can be recycled 100%, return packaging material separately.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Carmen CBS0301W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Carmen CBS0301W in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1.3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info