The filter D must be inserted between the tap B and the inlet hose A, remembering
to fit the washer C.
If the dishwasher is connected to new pipes or to pipes which have not been in use
for a long time run water through for a few minutes before connecting the inlet hose.
In this way no deposits of sand or rust will clog up the water inflow filter.
Connecting the outlet hose
The outlet hose should disharge into a standpipe, making sure that there are no kinks
(fig. 4).
The standpipe must be at least 40 cm above floor level and it must have an internal
diameter of at least 4 cm. It is advisable to fit an anti-odour air trap (fig. 4 x).
If necessary the outlet hose can be extended up to 2,6 m, provided that it is kept at
a maximum height of 85 cm above floor level.
The hose can be hooked over the side of the sink (it must not be immersed in water,
in order to prevent water from being syphoned back to the machine when this is in
operation) (fig. 4 y).
When installing the appliance under a worktop the hose pipe clamp must be attached
to the wall in the highest possible position under the worktop (fig. 4 z).
Check that there are no kinks in the inlet and outlet hoses.
123
4
Plug your dishwasher into the power socket.
If the plug we supply does not fit
• CUT ITOFF AND DESTROY IT!
You can't use it on other appliances, and the exposed wires could be
dangerous if anyone plugged it in.
• Fit a suitable plug, as follows:
Connect to the terminal in the plug
green and yellow wire marked with the letter E,
OR marked with the Earth symbol,
OR coloured green,
OR coloured green and yellow.
blue wire marked N
OR coloured black.
brown wire marked L
OR coloured red.
"WARNING"
THIS APPLIANCE MUSTBE EARTHED
Fuses and plugs
This appliance should be used only on a
socket with a minimum rating of 13 Amp.
Our ready-fitted plug is already equipped
with a 13 amp fuse which is BS 1362 ASTAapproved.
Any replacement should be exactly the same.
If the fuse cover is lost, do not use the plug until it is replaced.
A correct replacement fuse cover (obtainable from your dealer
or Electricity Board) must be the same colour as shown or
named on the insert on the base of the plug.
For U.K. only
26
Water connection
The inlet and drain hoses can be directed to left or right.
The dishwasher can be connected to either cold or hot water, as long as it is
no hotter than 60 °C.
Water pressure must be between 0,08 MPa and 0,8 MPa. If the pressure is below
the minimum consult our service department for advice.
The inlet hose must be connected to a tap so that the water supply can be cut off
when the machine is not in use (fig.1 B).
The dishwasher is fitted with 3/4" threaded connector (fig. 2).
Connect inlet hose A to water tap B with a 3/4" attachment making sure that it has
been properly tightened.
If it is necessary to lengthen the inlet pipe, an extension pipe can be fitted.
If limescale deposits or sand are present in the water, it is advisable to obtain the
appropriate filter, art. 9226085, from the Service Centre (fig. 3).
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Candy dfi 105 t at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Candy dfi 105 t in the language / languages: English, German, Dutch, French, Polish, Portuguese, Spanish, Spanish as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info