Important: Always switch off and remove the plug from the electricity supply
before cleaning the condenser.
To maintain the efficiency of the dryer regularly check that the condenser is clean.
To remove the condenser
1. Gently pull the bottom of the kickplate so that it unclips from the dryer. The
top section can then be unhinged allowing the kickplate to be completely
removed.
2. Turn the two locking levers anti-clockwise and pull out the condenser.
3. Pull out the condenser unit.
4. Gently remove any dust or fluff with a cloth,
then wash the unit by holding it under a
running tap turning it so that water flows
between the plates, to remove any dust or fluff.
5. Refit the condenser ensuring it is in the correct
way (as indicated by the arrow) and pushed
firmly into place. Lock the two levers by turning
them clockwise.
6. Refit the kickplate.
The Sensor Dry machine gives many options for
drying the laundry to suit all circumstances.
Note: The sensor may not detect a small load of
small articles. For small loads and separate items
or pre-dried fabrics with low moisture content,
use the timed programmes. Set the programme
between 30 and 75 minutes depending on the
14
Condenser
Selecting the
Programme