Installation: Electrical requirements
ELECTRICAL REQUIREMENTS FOR SWIM SPA (EUROPE)
Your swim spa runs on 230V 50Hz single phase. There are two
configurations you can run your swim spa on.
The minimum supply current is 50 amps, in this configuration the
heater will disengage if all 4 pumps are turned on.
The second option is to have the heater on even when the spa is
running at full speed; in very cold climates this may be desirable
especially if using the spa outdoors in winter continually. In this
configuration a 60 amp supply is required.
The size of the wire required will be determined by the distance to
the supply and the shielding method; your electrician will be able to
advise you of the required wiring for your specific situation.
Access
The Swim spa will arrive assembled as a single unit on a pallet. It will
weigh approx one metric ton and cannot be disassembled. For this
reason you will need to have a crane or other mechanical method of
unloading the spa and getting it to your chosen site.
We recommend you book a contract lift where the lifting company
will assess the situation and method of lift and carry insurance in
case of accidental damage to the spa or the property. The spa
warranty does not cover damage from installation. It is the
responsibility of the customer or his agents be it crane company or
lift operator to assess the lift and control all aspects of the moving
of the spa. Canadian Spa Company will not take responsibility for
any part of the moving of the spa, and cannot advise on the methods
used to move the spa.
Base
The base for your swim spa must be a flat level surface that contacts
the entire base of the spa. We recommend 15 cm of re-enforced
concrete but any flat level base that is stable and will not shift or
settle will suffice. If sinking your spa into the ground you need to
provide adequate drainage for water so that the hole the spa sits in
cannot flood as this will damage the electronics and electrical
components. Also at least a metre of access to the entire front of the
spa filters is required for component access. You are responsible for
providing adequate access in order to repair the spa in case of fault.
CIRCUIT BOARD CODES:
E = 1 x Earth Screw
S = 7 x Standard Screws
H1 = Heater Connection ‘1’
H2 = Heater Connection ‘2’
SA = Sensor Port ‘A
SB = Sensor Port ‘B’
T-Pad 1/2/3 = Topside Ports 1, 2 & 3
(Molex Connector)
JUMPER:
J8 = Jumper on 1 pin when using 2kW
or 1kW Heater. Jumper on 2 pin when
using 3kW Heater
J91 = Jumper on 1 pin enables Real
Time Clock function (ML900), Jumper
on 2 pin disables RTC function
1-Spd P2
Blank
Mp3
2-Spd P1
Not Used Ozone
Light
T-pad 1 T-pad 2T-pad 3
H1
H2
30
E
S
S
SS
S
S
S
3a Light Fuse
30a Pump 1 Fuse
2a Mp3 Fuse
10a Blower Fuse
30a Pump 2 Fuse
SA SB
J91
J8
J59
J36
J58
55596 c/board
NanswGL2km3 Circuit Board (Swim spa models: St Lawrence 13’ and 16’ Swim Spa)
Expander Board - 55026: for pump 3
&4 (split plug)
Pump 3 & 4
30 A Pump fuse
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Yukon at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Yukon in the language / languages: English as an attachment in your email.

The manual is 3,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Yukon

Canadian Spa Company Yukon User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info