764877
9
Zoom out
Zoom in
Previous page
1/32
Next page
Owners Manual
9
Installation: Electrical requirements
Canadian Spa Company requires that the electrical installation of
your hot tub is carried out by a professionally licensed electrician and
that all local electrical and building codes are adhered to.
Access to the electrical pack can be found by removing the panel
directly below the topside control.
CONNECTING HOT TUB TO RCD AND CONSUMER PANEL:
All hot tubs must be wired with the appropriate sized wiring.
Failure to do so will cause equipment damage and will not be
covered by your warranty
All hot tubs must be protected with a appropriately sized RCD
(Residual Current Device) in the consumer panel. Have your
electrician verify using the diagram opposite.
ADDITIONAL ITEMS NEEDED TO HELP COMPLETE ELECTRICAL
CONNECTION:
1. RCD Breaker, 2. Electrical cable (check length and width for
amperage and distance), 3. Cable gland., 4. Tidy clips.
IMPORTANT: The electrical wiring of this spa must meet the
requirements of any applicable local codes. The electrical circuit
must be installed by a qualified electrician and approved by a local
building/electrical inspection authority.
1. This spa must be permanently connected (hard wired) to the
power supply. No plug-in connections or extension cords are to
be used in conjunction with the operation of the spa.
Supplying power to the spa which is not in accordance with
these instructions will void both the independent testing agency
listing and the manufacturer’s warranty.
2. The power supplied to this spa must be a dedicated circuit with
no other appliances or lights sharing the power provided by the
circuit.
3. To determine the proper wire size, see Power Requirements
section.
a) Wire size must be appropriate per local codes.
b) All wiring must be copper to ensure proper connections. Do
not use Aluminum wire. Using Aluminum wire will void the
manufacturer’s warranty.
4. Although not required, but recommended the installation of a
suitably rated isolator switch for ease of power connection and
accessibility.
5. The electrical circuit supplied for the spa must include a suitable
Residual Circuit Device (RCD) having a rated residual operating
current not exceeding 30 mA.
IMPORTANT: For supply connections, use conductors sized on the
basis of amperage but rated for 75°C (167°F).
6. An RCD breaker must be used in order for the spa to function
properly.
7. To gain access to the spa’s power terminal block, remove the
screws to the access panel located under the Topside Console.
Remove the cover to the spa controller.
8. Feed the supply power cable through the side of the spa or from
underneath the unit. Use the appropriate cable gland to secure
the power supply.
9 Connect the wires, colour to colour on the terminal block.
TIGHTEN SECURELY (all wires must be connected securely or
damage could result).
10. After connecting your electrics close the spa control box cover
and replace the spa access panels.
Electrical Installation 50 Hz (U.K. / Europe)
Spa Model Voltage Min RCD Size*
Yukon Plug & Play 230V 13A
Quebec Plug & Play 230V 13A
Winnipeg Plug & Play 220V 13A
Toronto 230V 20A
Thunder Bay 230V 25A
Niagara 230V 32A
Vancouver 230V 32A
Victoria 230V 25A
Alberta 230V 32A
Halifax 230V 25A
Montreal 230V 25A
St Lawrence 13’ Sport Pool 230V 42A
St Lawrence 16’ Swim Spa 230V 48A
Consumer panel
RCD Breaker
Hot tub control box
3. Hot tub Control box1. Consumer Panel
(RCD Protected)
2. Outside isolation
switch
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Winnipeg at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Winnipeg in the language / languages: English as an attachment in your email.

The manual is 3,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Winnipeg

Canadian Spa Company Winnipeg User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info