764874
14
Zoom out
Zoom in
Previous page
1/32
Next page
Owners Manual
14
Starting your hot tub/spa
POWERING UP YOUR SPA
Once the spa is properly wired and filled with water, the spa power can
be turned on and Start-up chemicals added.
1. Turn on RCD breaker. If breaker trips immediately check
Neutral and Ground Wire connections. Upon initial power up,
4 sets of numbers flash on the LED display of the topside
Console. The last number in the sequence is the incoming
power meter which can be used to verify that the spa is wired
correctly.
2. The spa begins an automatic priming routine which will last 6
minutes (“Pr” is on the LED display).
3. The priming routine will automatically run each spa pump to
prime. When the “Pr” is displayed, press any PUMP button
to prime that pump or wait for the priming routine to turn
on the Pump. IMPORTANT: To avoid pump damage, do not run
pumps for more than 1 minute without moving water. If no water
is moving, turn the power off and perform air lock procedure.
4. The Topside Console display flashes “100F” then press “--F” for
approximately 2 minutes to determine water temperature as it
flows through the heater.
5. The default pre-set temperature is 36.5°C. The last measured
temperature is constantly displayed on the LCD readout. This
temperature will be current only when the pump has been
running for at least 2 minutes. Set the desired temperature
between 80-104°F (26- 40°C) by pressing the temp button(s).
If the water temperature is below the set temperature, the spa’s
heater and heat indicator light will turn on. All features of
the Topside Console will be available. The spa will heat
approximately 1° every 30 minutes per 1,000 litres.
6. Check for leaks! Although spas are fully checked at the factory,
shipping & delivery might cause a leak. Remember to pay
particular attention to barrel unions adjoining the heater.
Contact your Canadian Spa dealer directly if there is a problem.
If your new spa pump does not prime (flow) on the initial start-up you
may be experiencing an “air lock”.
This normal occurrence can be easily corrected by loosening the
plumbing union on the suction side of the Jet or Circulation Pump until
water flows into the pump and all air is expelled.
PRESS BUTTONS SLOWLY FOR FIRST RUN WHEN STARTING UP
ONCE PR EXITS, SET TEMPERATURE ON SPA (SEE SPA OPERATION
SECTION FOR DIFFERENT SPA TOPSIDES)
The above photograph refers to plug and play models only
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Toronto at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Toronto in the language / languages: English as an attachment in your email.

The manual is 3,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Toronto

Canadian Spa Company Toronto User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info