764874
10
Zoom out
Zoom in
Previous page
1/32
Next page
Owners Manual
Installation: Electrical power requirements
Single Phase 3 wires (live, neutral, ground)
230VAC, 50/60Hz*, 1þ, 32A, (Circuit Breaker rating = 40A max.)
For Single Phase connection (1 x 32A):
1. Put DIP switch A2 on ON and DIP switch A5 on OFF
Power connections
Single Phase (A) is the normal wiring configuration for most houshold electrical installations (3 wires: live, neutral and earth). If however you
have insufficient Amps you will need to use other connection(see below). 2 Single Phase connection (B) is used in circumstances where the
power supply is limited and where you need more Amps. 3 Phase (C) is used in certain areas of Europe where 3 Phase power is available and
the installation warrants it. NOTE: Canadian Spa Company requires that the electrical installation of your hot tub is carried out by a
professionally licensed electrician and that all local electrical and building codes are adhered to.
A.) Single Phase connection (Most common):
NBP6013H Circuit Board (Spa models: Toronto, Winnipeg, Thunder Bay, Halifax, Montreal, Yukon, Quebec, Alberta, Niagara, Ottawa, Victoria,
Vancouver)
Template 56377 10-05-12 56751_97_B 07-07-15
5
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.
Wiring Diagram
Hardware Setup
F4 3A SLO-BLOW
J31
J30
115V 115V
230V
F3 0.125A SLO-BLOW
J25=HTR1
J26=HTR2
J27=HTR3
J30=TEST
J31=CE
HTR
SEL
F7 10A 250VAC
F2 10A 250VAC
TB1
J15
ON
10
S1
K5
K1
K3
T1
K2
K4
K8
LIGHT
GND
J33 J21 J32
J9
1
2
3
4
Print Offsets:
+10 Top
+0020 Left
PART A
4
3
2
1
J45
J110
J79
J54
J72
J42
J3
J37
J4
J1
J61J47
J77
J75
J78
J36
J60
J46
J38
J39
J111
J53 J58
J11
J41
J6
J7
J19
J13
J12
J88
J62
F6 30A
F8 30A
J56
J57
J55
J59
J51
J52
J98
J10
J81
J20
J18
J43
CIRC PUMP
OZONE
A/V HOT
PUMP 1
J14
K9
J5
AUX
J35
MAIN
J34
MAIN
J22
J23
SERIAL
J28
AUX
FRZ
J17 J16
J101
J24
J107
K7
TP (MAIN) PANELS
J34 OR J35
07-07-15
NBP6013H – PN 56751
PART A
J29
VAC HTR
DISBL
L1
3 X 16A
230VAC
32A
N (BL)L1 (BRN) L2 (BRN) L3 (BRN)
N
BROWN
BRAUN
BRUN
BLUE
BLAU
BLEU
AUX J5 (A1-A4)
GRN
BLU
BRN
230V
1x32A
SENSOR B
SENSOR A
3.0 kW HEATER
HEIZELEMENT
RADIATEUR
3
2F5 10A 250V EXPANDER
X-B
J3
BLOWER
K1
J6
J2
W12
LOCATION DEVICE VOLTS AMPS FROM TO FROM TO
J6 ON BLOWER 230V 4A W12 ON GROUP 2 J3 ON F8 GROUP
EXPANDER MAX EXPANDER J1 EXPANDER J10
VENTILATEUR SPRUDELGEBLASE
PUMP 2
WIFI
TRANSCEIVER
J34 OR J35
J48J49
CIRCUIT BOARD CODES:
E = 1 x Earth Screw
S = 6 x Standard Screws
SA = Sensor Port ‘A
SB = Sensor Port ‘B’
J35 = Main Topside Port 1J34 =
Main Topside Port 2 J11 = J110
Earth Connector, J111 Earth Con-
nector
Expander Board
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Toronto at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Toronto in the language / languages: English as an attachment in your email.

The manual is 3,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Canadian Spa Company Toronto

Canadian Spa Company Toronto User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info