7
Locating your hot tub/spa
INDOOR LOCATION
Considerations for selecting an indoor spa location:
Local building codes for indoor installation of a portable spa
Adequate space for spa with accessibility for service (Clearance
of 3 ft (1m) around the spa is recommended to permit servicing
the unit)
Proper structural support is critical. Consult a licensed
professional Structural Engineer to determine if the foundation
will adequately support the spa the entire time it will be in place,
especially if the spa is to be placed on a second story or higher,
balcony, roof or other platform not specifically tied into the main
structural support.
Proper ventilation (Consult an Engineer or authority who
understands the necessary provisions to vent moist or heated air
and air with chemical odours. When the spa is in use
considerable amounts of moisture escapes, potentially causing
mould and mildew which can damage certain surfaces and
surroundings.
POSITIONING YOUR HOT TUB/SPA
When selecting a site for your spa, take into account the following:
A) Local Codes:
There may be certain restrictions and/or requirements that are
particular to your locality. If in doubt, check with your local council.
B) Delivery Passageway:
The spa will arrive as a unit, and cannot be disassembled. Ideally the
spa will be placed on a trolley, either on its side or on its base. The
unit will then be rolled into place easily crossing grass, gravel, and
small terrain anomalies. For safe and non-intrusive installation, we
require an opening not less than the width of your spa (see dealer
for current sizes) plus at least 40cm in height for the trolley and a
minimum of 5cm clearance on each side for adequate access. If
your access does not meet these conditions, or in the case of other
obstacles (steps, fences, walls, steep hills, etc.) contact Canadian Spa
Company for advice and conditions.
C) Location & Base:
A sheltered environment can result in lower operating and
maintenance costs. You must allow 1 metre clearance for access to
the spa’s access panel for servicing.
The site you select for your spa MUST be a flat, level continuous
surface that fully contacts the bottom of the spa.
Your new spa weighs between 300-450kg when dry, and when
filled to capacity weighs 900-2300kg. Therefore a solid support
is essential when the spa is mounted on a deck or ground level
patio/floor. We recommend that you install your spa at ground
level. This allows easy access to equipment.
A 10 to 15cm thick re-enforced concrete slab is ideal, but not
essential. In most cases your spa can be placed on properly
installed existing patios.
The base must be at least the size of the bottom of your spa (see
dealer for current sizes).
Water should always drain away from the spa. DO NOT locate
your spa in a low run-off area since melting snow or rain could
flood the area and cause pump and equipment damage.
DO NOT situate the spa near or under overhead wires and keep
clear of all electrical appliances.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Canadian Spa Company Ontario 2016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Canadian Spa Company Ontario 2016 in the language / languages: English as an attachment in your email.

The manual is 3,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info