21. Retaining screw
22. Wedging block for upper filter
20. Window seal plate assembly
23. Wedging block for lower filter
ASSEMBLING
Before first use, assembly the device as below:
1. The device should be placed on a flat surface. The distance to wall or other objects shall be least 50 cm to not limit air flow – look at
picture 6. Do not install and use the device in the bathroom or other high humid environments.
7. The units ( <-> ) of required room temperature can be changed by pressing button (16) on remote control or simultaneously press
both buttons up key (11) and down key (11) to switch between Celsius () and Fahrenheit ().
2. Press the button (12) to select one of the available modes: COOL -> FAN -> DRY
DEVICE OPERATION
3. Elongate the exhaust pipe (19) and snap the flat end of the heat pipe joints into the elliptical hole of the window sealing plate assembly
(as shown on picture 6).
a) Half open the window, and mount the window sealing plate assembly (20) to the window (as shown on picture 5); the assembly (20) can
be placed in horizontal and vertical direction.
MANUAL DRAINAGE: When water in the water pan exceeds the warning level, the device will automatically sound an alarm and the LCD
display (14) area will show "FL". Also the FULL water control lamp (18) will light up. Then turn off the device and remove the plug from the
8. Press the button (15) to start the air oscillation, the blinds will move vertically. Press it again to stop air oscillation.
5. When the device is turned off it can be turned on with a delay by pressing the TIMER button (9). Press the UP / DOWN buttons (11) to
set the time for the device to be activated by selecting the time in the range of 1-24 hours. When the device is turned on it can be turned off
with delay by pressing the TIMER button (9). Press the UP / DOWN buttons (11) to set the time for the device to be switched off by
selecting the time in the range of 1-24 hours.
4. During COOL or FAN modes use FAN button (10) to set the fan speed: STRONG (F3), MEDIUM (F2), WEAK (F1). But wind speed
operation is limited by anti-cold conditions, under certain conditions, it may not run according to the set wind speed. In DRY mode fan is
automatically set to level WEAK.
4. The length of the exhaust hose shall be 280~1,500mm, it cannot be distorted nor has substantial turning (greater than 45°). Exhaust
must be unobstructed; otherwise it may cause overheating. Do not use extension tubes or replace it with other different hoses, or this may
cause a malfunction.
After connecting the device to the mains, the buzzer will play power-on music, it will go into standby mode and will display the present
ambient temperature.
3. In the COOL mode, set the temperature using the UP / DOWN buttons (11). It is not available in fan and dehumidification mode.)
DRAINAGE INSTRUCTIONS
Notes: 1. the flat end of the exhaust pipe joints must be snapped into place.
1. To turn on or off the device, press the button (13).
6. By pressing simultaneously the UP button (11) and FAN button (10) or by pressing the button SLEEP (17) on remote control the device
can be switched to sleep mode. The device will then operate quietly in the energy-saving mode. This function is only available in COOL
mode, not available in FAN and DRY modes.
b) Pull various components of the window sealing plate assembly open, adjust opening distance to bring both ends of the assembly into
contact with the window frame, and fix components of the assembly.
2. Install the window sealing plate assembly (20):
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camry CR 7907 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camry CR 7907 in the language / languages: All languages as an attachment in your email.

The manual is 19,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info