Please read the instructions carefully before use.
Use outdoors only
• Do not use charcoal as a substitute for, or in addition to, lava rock.
Do not use an adjustable low pressure regulator. Use fixed regulators that comply with the European standard
concerning them.
Do not cover the bottom of the base with aluminium foil.
Never put a metal plate, that has neither been designed nor recommended by CAMPINGAZ, on (or in the place
of ) the lava rocks.
Follow these instructions carefully to avoid seriously damaging your barbecue.
Operation and maintenance
Connect the flexible tubing to the coupling on the barbecue
and the connector on the regulator by following the
instructions supplied with the connector assembly (couplings).
Test the seal with gas a leak solution.
Hose length should not exceed 1.25 meters. Do not pull or
pierce the hose. Check that the flexible hose stretches out
normally without twisting or pulling and does not come into
contact with the hot sides of the barbecue. It should be
replaced when the expiry date on the hose is reached or
whenever it is damaged or develops surface cracks.
Belgium, Luxembourg, United Kingdom, Ireland,
Portugal, Spain, Italy, Croatia, Greece, Netherlands,
Czech Republic, Slovakia, Hungary, Slovenia, Norway,
Sweden, Denmark, Finland, Bulgaria,Turkey, Romania,
Poland:
The barbecue is equipped with a circular connector. It should
be used with flexible hose UK that is suitable for use with
butane and propane gas. hose UK length should not exceed
1.20 meters. It should be replaced if it is damaged or cracked,
when required by national regulations or at the end of the part
lifecycle. Do not pull or pierce the hose.
Keep away from any parts of the barbecue that get hot. Check
that the flexible hose stretches out normally, without twisting
or pulling.
Switzerland, Germany,Austria:
The barbecue should be used with flexible tubing that is
suitable for use with butane and propane gas. Tubing length
should not exceed 1.50 meters. Do not pull or pierce the
tubing. It should be replaced if it is damaged or cracked, when
required by national regulations or at the end of the part
lifecycle. Do not pull or pierce the tubing. Keep away from any
parts of the barbecue that get hot. Check that the flexible hose
stretches out normally, without twisting or pulling.
Flexible tubing connection:
To connect the tubing to the
connector on the barbecue,tighten the nut on the tubing firmly
but without excess force using the two wrenches provided:
- no. 10 wrench to tighten the connector
- no. 17 wrench to tighten the nut on the tubing
e) Lid (depending on model)
Handle the lid carefully,especially during operation.Do not lean
over the base
f) Checking for gas leaks
1) Work outside, away from all sources of ignition. Do not
smoke.
2) Make sure the control knobs are in the "off" (l) position.
3) Push the end of the hose completely onto the regulator
nozzle and secure with a suitable clip.
a) For your safety
- Do not store or use petrol and other flammable liquids or
vapours in the vicinity of this barbecue. If you smell gas:
1) Close the valve of the cylinder
2) Extinguish all naked flames
3) Open the lid
4) If the smell continues , see F or immediately seek advice
from your local retailer.
b) Location
- This barbecue must only be used outdoors.
- Caution: accessible parts may get very hot. Keep young
children away.
- There should be no combustible materials within a radius of
approximately 60 cm around the barbecue
- Do not move the barbecue when alight.
- The appliance should be operated on a level surface.
- Estimated air offtake 2 m
3
/kW/h.
c) Gas cylinder
- This barbecue has been adjusted to be operate off 4,5 to 15
kg butane/propane cylinders with an appropriate low pressure
regulator.
- France, Belgium, Luxembourg, United Kingdom,
Ireland, Portugal, Spain, Italy, Croatia, Greece: butane
28-30 mbar / propane 37 mbar.
- Netherlands, Czech Republic, Slovakia, Hungary,
Slovenia, Norway, Sweden, Denmark, Finland,
Switzerland,Bulgaria,Turkey,Romania:butane 30 mbar
/ propane 30 mbar.
- Poland: propane 37 mbar.
- Germany,Austria: butane / propane 50 mbar.
- Always connect or replace the cylinder in a well-ventilated
area, never in the presence of a flame, spark or heat source.
d) Hose
France (depending on model):
The unit is equipped with a G1/2 threaded inlet coupling. A
circular connector and rubber gasket are also supplied for the
butane/propane bottle.
Depending on the construction of your regulator, follow these
instructions:
1) F
or regulators equipped with an M20 x 1.5 threaded
outlet:
Use reinforced flexible tubing that complies with the XP D 36-112
standard. Screw the G1/2 tubing coupling onto the connector on
the barbecue. Screw the M20 x 1.5 threaded connector onto the
regulator outlet.Test the seal with gas leak solution.
2) F
or regulators equipped with a circular coupling:
Use a connector assembly (flexible tubing + collars) that
complies with the XP D 36-110 standard. Screw the circular
coupling supplied with the unit to the threaded connector,
inserting the rubber gasket between them.When the gasket is
in contact with the connector, tighten approximately one half
turn.
M 20x1,5
Regulator
G 1/2
barbecue
M 20x1,5
Regulator
G 1/2
barbecue
black
6
GB
76622-04.qxp 12/03/2013 13:49 Page 6
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Campingaz Expert 2 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Campingaz Expert 2 Plus in the language / languages: All languages as an attachment in your email.

The manual is 1,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info