GB
POSSIBLE PROBLEMS / CORRECTIVE ACTION
Possible problems Probable causes / Corrective action
The burner does not light up
Poor gas supply
regulator not operating properly
Pipe, valve, venturi tube or burner holes obstructed
The burner does not burn smoothly or goes out
Check that gas is present
Check the pipe connection
Contact your servicing agent."
Unstable blowing flames
New cylinder may contain air. Allow the appliance to operate and the
fault will clear itself
Residual water, following the washing of the burner caps
Contact your servicing agent.
Large plume of flame on the burner surface
The venturi is obstructed (possibly cobwebs)
Contact your servicing agent."
Flame at the injector
The cylinder is almost empty
Change the cylinder and the fault will clear itself
Contact your servicing agent.
Burning leak around a union
Shut off the gas supply immediately
Leaking union: tighten nuts or change pipe
Contact your servicing agent.
Insufficient heat
Injector or venturi tube obstructed
Contact your servicing agent.
Burning leak behind the adjustment knob
Defective valve
Shut down the stove
Contact your servicing agent.
WARANTY PERIOD 
Years 2
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Campingaz 200 SGR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Campingaz 200 SGR in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Portuguese, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 27,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info