810632
28
Zoom out
Zoom in
Previous page
1/40
Next page
28
Repair hints
Operation with closed fire box in accordance with EN 13229 Lina GT
7363
Lina
7345 s/h
7351 s/h
7357 s/h
7363 s/h
Lina
8745 h
8751 h
8757 h
Lina
8770 h
Lina
10045 h
10051 h
10057 h
Lina
12045 h
12051 h
12057 h
Lina TV
4545 s/h
4551 s/h
4557 s/h
4580 h
Nominal heat output kW 6 9 10 19 10 10 7
Thermal output range kW 4.4–6.3 3.2–10.9 4.6–10.1 8.0–19.2 3.2–10.9 4.9–10.6 3.4–7.8
Room heat output kW 6 9 10 19 10 10 7
Heat distribution: through the viewing window % 25 35 35 35 35 40 50
Heat distribution: convective output % 75 65 65 65 65 60 50
Suitable for multiple flue connections to the chimney 
Flue gas connector Ø inmm 180 200 200 200 200 200 180
Combustion air connector Ø inmm 125 150 150 150 150 150 125
SMR combustion control 
recommended free cross-section1Supply air (cm2) 1080 1410 1560 2970 1560 1440 840
Recirculation air (cm2) 900 1170 1300 2470 1300 1200 700
Combustion air requirement m³/h 24 36 40 76 40 40 28
Recommended quantity of wood, approx. kg 2.5 4.0 4.5 5.5 5.0 5.0 3.0
Recommended quantity of wood with NHK, approx. kg --- 5.5 5.5 --- 9.0 --- ---
Recommended quantity of wood with heat storage
system, approx. kg 4.5 6.0 --- --- --- --- 5,5
Recommended length of logs cm 33 33 33 33 33 33 33
Fuel conversion kg/h 1.8 4.7 --- --- --- --- 5.1
Minimum distance to the fire box
(in accordance with TR OL 2006, version 2010) mm 800 800 800 800 800 800 800
Minimum distance to the insulation
(in accordance with TR OL 2006, version 2010) mm 60 90 100 100 100 100 70
Insulation thickness (with awall that does not need to
be protected) (based on SILCA® 250KM) mm 60 60 60 60 60 60 60
Weight kg 230 230-290 280-320 350 310-350 340-400 190-250
Fuel Type Wood Wood Wood Wood Wood Wood Wood
Triple values
with nominal
heat output
Flue gas mass flow g/s 6.2 9.1 8.9 17.8 10.1 7.9 7.5
Flue gas temperature °C 214 320 320 263 320 365 330
Required delivery pressure Pa 12 12 12 12 12 12 12
Triple values for connecting
ceramic flues
(wood used as fuel)
Firing power kW 15 19.8 --- --- --- --- 18.2
Flue gas mass flow g/s 14.5 16.7 --- --- --- --- 14.7
Flue gas temperature
upstream of the connecting surface °C 418 345 --- --- --- --- 337
Required delivery pressure at the flue
gas connector Pa 15 15 --- --- --- --- 15
Combustion air requirement m³/h 56 59.6 --- --- --- --- 63,9
Recommended flue length2m --- 3.5 3.5 --- 3.5 3.5 3.5
Emission
values
Wood fuel
CO - based on 13 % O₂ mg/Nm³ < 1250 < 1250 < 1250 < 1250 < 1250 < 1250 > 1250
Dust - based on 13% O₂ mg/Nm³ < 40 < 40 < 40 < 40 < 40 < 40 < 40
Eiciency % > 80 > 78 > 78 > 78 > 78 > 80 > 78
Minimum heat-emitting surface3
(based on closed design) 2.7 4.0 4.4 7.6 4.4 4.1 2.4
Ecodesign Regulation in accordance with (EU) 2015/1185 
Energy eiciency class in accordance with (EU) 2015/1186
Energy eiciency index (EEI) 112.7 103.4 103.2 103.2 103.4 106.6 103.7
Declaration of Performance No. LE1260504-1 LE29061074-2 LE29102338 LE848363-1 LE29061074-3 LE29102334 LE29061106
possible
connected
equipment
Top mounted heat exchanger --- --- --- --- ---
Hot air top-mounted element --- --- --- ---
Heat exchanger --- --- --- ---
Eiciency with connected equipment % --- > 80 > 80 --- > 80 --- ---
Hot water top-mounted element (HWAR R) --- --- ---
4
s = hinged door, h = guillotine door, TV = tunnel version
The specified waterside output was determined under test conditions. The achievable output can vary
depending on the flue liner, quantity of wood and pump assembly used.
1 The calculation was based on “TR OL 2006, edition 2010 – Table 17: Free cross-section in cm² for grille or
opening tile based on the thermal output for air heating” with the preferred air velocity of 0.75 m/s. Supply air
grille 240 cm2 / kW, recirculation air grille 200 cm² / kW.
2 The information regarding flue lengths is a recommendation and based on the
calculation in accordance with TR OL 2022 chapter 15. The calculation is based on a
medium-heavy design and a flue ratio of 360 cm².
4 With the exception of height 80 cm
3 Average value based on the storage time. Depending on the material properties
and the construction thickness.
Mean specific heat distribution = approx. 500 W /
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Lina at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Lina in the language / languages: English as an attachment in your email.

The manual is 5.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Lina

Camina-Schmid Lina User Manual - German - 40 pages

Camina-Schmid Lina User Manual - Dutch - 36 pages

Camina-Schmid Lina User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info