810636
14
Zoom out
Zoom in
Previous page
1/44
Next page
14
Safety
1.13 Safety equipment
1.13.1 Thermal discharge safety device (TAS)
The thermal discharge safety device in compliance with
EN 14597 protects the hot water circuit from excessively
high temperatures. A fresh water supply is triggered by
the thermal discharge safety device (TAS) when a higher
temperature (> 97 °C) is reached.
Fig. 10: Thermal discharge safety device (4 m capillarycable,
sensor pocket L = 148 mm)
1.13.2 Safety valve
A safety valve protects the heating circuit from excessive
pressures and needs to have a max. response pressure of
3.0 bar. The valve balances the system pressure if too high
apressure is reached.
Fig. 11: Example of a safety valve
1.13.3 Safety water heat exchanger
The hot water boiler is equipped with a safety water heat
exchanger. The integral safety water heat exchanger is used
for the emergency cooling-down of the fireplace in the event
of power failure and prevents overpressure in the boiler. The
heat exchanger and the requisite water feed and return lines
are isolated from the heating circuit. The cooling system is
activated when the thermal discharge safety device (TAS)
is triggered. Only use the safety water heat exchanger as a
safety device to prevent the hot water from overheating in
the boiler.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Lina-W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Lina-W in the language / languages: English as an attachment in your email.

The manual is 3.69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Lina-W

Camina-Schmid Lina-W User Manual - German - 44 pages

Camina-Schmid Lina-W User Manual - Dutch - 44 pages

Camina-Schmid Lina-W User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info