Technical data
Operation with closed fire box in accordance with EN 13229 Ekko U
45(34)45 h
45(34)51 h
45(34)57 h
Ekko U
55(45)45 h
55(45)51 h
55(45)57 h
Ekko U
55(67)45 h
55(67)51 h
55(67)57 h
Ekko U
60(90)51 h
Ekko U
67(45)45 s
67(45)51 s
67(45)57 s
Ekko U
67(45)45 h
67(45)51 h
67(45)57 h
Ekko U
84(34)45 h
84(34)51 h
84(34)57 h
Nominal heat output kW 4 9 9 14 9 9 10.5
Thermal output range kW --- --- 4.3–9.1 --- 3.4–9.8 3.0–9.0 ---
Room heat output kW 4 9 9 14 9 9 10.5
Heat distribution: through the viewing window % 70 70 70 40 60 65 60
Heat distribution: convective output % 30 30 30 60 40 35 40
Suitable for multiple flue connections to the chimney 
Flue gas connector Ø inmm 180 200 200 250 200 200 200
Combustion air connector Ø inmm 125 125 125 150 125 125 125
SMR combustion control --- 
recommended free cross-section1Supply air (cm2) 480 1080 1080 2184 1080 1080 1260
Recirculation air (cm2) 400 900 900 1820 900 900 1050
Combustion air requirement m³/h 16 32 36 54 36 36 42
Recommended quantity of wood, approx. kg 1.8 3.0 4.0 4.0 4.0 4.0 4.5
Recommended quantity of wood with NHK, approx. kg --- --- --- --- 7.0 --- ---
Recommended quantity of wood with heat storage
system, approx. kg --- 6.0 6.5 --- 6.5 6.5 ---
Recommended length of logs cm 25 (33 standing) 33 33 33 33 33 33
Fuel conversion kg/h --- --- --- --- --- --- ---
Minimum distance to the fire box
(in accordance with TR OL 2006, version 2010) mm 800 800 800 800 800 800 800
Minimum distance to the insulation
(in accordance with TR OL 2006, version 2010) mm 50 90 90 60 90 90 100
Insulation thickness (with awall that does not need to
be protected) (based on SILCA® 250KM) mm 60 60 60 60 60 60 60
Weight kg 150-170 210-230 240-260 370 190-210 240-260 280-320
Fuel Type Wood Wood Wood Wood Wood Wood Wood
Triple values
with nominal
heat output
Flue gas mass flow g/s 4.7 12.6 8.6 11.9 9.5 8.2 14.9
Flue gas temperature °C 255 228.5 310 310 330 345 259
Required delivery pressure Pa 11 12 11.5 12 12 12 12
Triple values for connecting
ceramic flues
(wood used as fuel)
Firing power kW --- 19.8 21.5 --- 21.5 21.5 ---
Flue gas mass flow g/s --- 33.7 29.7 --- 30.6 29.3 ---
Flue gas temperature upstream of the
connecting surface °C --- 280 361 --- 361 361 ---
Required delivery pressure at the flue
gas connector Pa --- 15 15 --- 15 15 ---
Combustion air requirement m³/h --- 75.4 75.6 --- 75.6 75.6 ---
Recommended flue length2m1.7 1.7 1.7 --- 3.5 3.5 ---
Emission
values
Wood fuel
CO - based on 13 % O₂ mg/Nm³ < 1250 < 1250 < 1250 < 1250 < 1250 < 1250 < 1250
Dust - based on 13 % O₂ mg/Nm³ < 40 < 40 < 40 < 40 < 40 < 40 < 40
Eiciency % > 80 > 78 > 78 > 80 > 78 > 78 > 80
Minimum heat-emitting surface3
(based on closed design) 1.8 3.7 3.5 4.1 3.5 3.5 4.0
Ecodesign Regulation in accordance with (EU) 2015/1185 
Energy eiciency class in accordance with (EU) 2015/1186
Energy eiciency index (EEI) 107.5 105.0 104.1 106.1 103.2 103.4 106.4
Declaration of Performance No. LE29143528 LE11080165 LE29102336 LE1459631-1 LE29061076-2 LE29102335 LE12030194
possible
connected
equipment
Top mounted heat exchanger --- --- --- --- --- --- ---
Hot air top-mounted element --- --- --- --- --- ---
Heat exchanger --- --- --- --- --- ---
Eiciency with connected equipment % --- --- --- --- > 80 --- ---
Hot water top-mounted element (HWAR R) --- --- --- --- --- --- ---
s = hinged door, h = guillotine door
The specified waterside output was determined under test conditions. The achievable output can vary
depending on the flue liner, quantity of wood and pump assembly used.
1 The calculation was based on “TR OL 2006, edition 2010 – Table 17: Free cross-section in cm² for grille or
opening tile based on the thermal output for air heating” with the preferred air velocity of 0.75 m/s. Supply air
grille 240 cm2 / kW, recirculation air grille 200 cm² / kW.
2 The information regarding flue lengths is a recommendation and based on the
calculation in accordance with TR OL 2022 chapter 15. The calculation is based on a
medium-heavy design and a flue ratio of 360 cm².
4 When installing the fireplace insert in a set with a storage stone system, the
values specified in the relevant installation instructions apply.
3 Average value based on the storage time. Depending on the material properties
and the construction thickness.
Mean specific heat distribution = approx. 500 W /
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Ekko at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Ekko in the language / languages: English as an attachment in your email.

The manual is 4.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Ekko

Camina-Schmid Ekko User Manual - German - 44 pages

Camina-Schmid Ekko User Manual - Dutch - 44 pages

Camina-Schmid Ekko User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info