1.11.2 Parts made of combustible materials
1.11.2.1 Within the radiation range
Adhere to the following safety distances with regard to
parts made of combustible materials or combustible parts,
including fitted furniture, installed close to fireplaces:
There needs to be aspacing of at least 800mm from the
front/top and sides of the fire box opening to combustible
components. adistance of 400mm is enough if aradiation
shield is fitted, vented on both sides. The distance of the
ventilated radiation protection needs to be at least 20mm.
min. 800mm
min.
400mm
min. 20mm
Fireplace
A
B
Fireplace insert
Fig. 5: Protection of combustible components in the
radiation range of the fire box opening: Ekko
min. 800mm
min.
400mm
min. 20mm
Fireplace
A
B
Fireplace
insert
Fig. 6: Protection of combustible components in the
radiation range of the fire box opening: Ekko
Description:
A = Ventilated radiation protection
B = Parts made of combustible materials, furniture, fabrics
1.11.2.2 Outside the radiation range
Ensure the following safety distances with regard to parts
made of combustible materials or combustible parts,
including fitted furniture:
There needs to be aminimum distance of 50mm from the
free outside surfaces of the surrounding facing the location
of the fireplace to combustible materials or combustible
components and fitted furniture.
min. 50mm
Fireplace
A
Fireplace insert
Fig. 7: Protection and distances with heated surfaces: Ekko
min. 50mm
Fireplace
A
Fireplace
insert
Fig. 8: Protection and distances with heated surfaces: Ekko U
Description:
A = Parts made of combustible materials, furniture, fabrics
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Camina-Schmid Ekko at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Camina-Schmid Ekko in the language / languages: English as an attachment in your email.

The manual is 4.99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Camina-Schmid Ekko

Camina-Schmid Ekko User Manual - German - 44 pages

Camina-Schmid Ekko User Manual - Dutch - 44 pages

Camina-Schmid Ekko User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info