The 840W features a Control Bus input/output
that allow un-modulated remote control
commands (positive logic, TTL level) to be received
electrically by the unit and looped to another unit
if desired. These control commands are typically
generated by custom installation (multi-room) systems or remote IR
receiver systems. The Control Bus sockets are colour-coded orange.
An IR Emitter Input is also provided that allows modulated IR remote
control commands to be received electrically by the unit. Commands on
this input operate the unit only and are not looped out demodulated on
the Control Bus Output.
The unit responds to ‘direct’ IR/Control codes as well as toggle codes for
some features to simplify programming custom installation systems.
Special direct On/Off and Mute commands can be accessed from the
840E pre-amplifier remote control for teaching into C.I. systems as
follows:
1. Press and hold the Standby/On button. The remote first generates a
standby (toggle) command. Keep the button held down, after 12
seconds an amplifier “On” command will be generated. If the button
is kept held down for a further 12 seconds, an amplifier player “Off”
command is generated.
2. Press and hold the Mute button. The remote first generates a mute
(toggle) command. Keep the button held down, after 12 seconds a
“Mute on” command will be generated. If the button is kept held
down for a further 12 seconds, a “Mute off” command is generated.
These commands are recognised by the 840W via the IR Emitter input.
A code table for this product is available on the Cambridge Audio
website:
www.cambridge-audio.com
Custom installation (C.I.) use
IR Emitter
In In Out
Control Bus
Power Output - Stereo/Mono 200W per channel 8 Ohms
350W per channel 4 Ohms
Power Output - Bridged Mono 500W 8 Ohms
800W 4 Ohms
THD (unweighted) < 0.001% 1kHz
< 0.005% 20Hz - 20kHz
Frequency Response 5Hz - 80kHz -1dB
S/N ratio (ref 1W/8 Ohm) > 90 dB (unweighted)
Sensitivity Stereo or Mono =
(for 200W 8 Ohms) 1.5V rms unbalanced
1.5 + 1.5V rms balanced
Bridged Mono =
0.775V rms unbalanced
0.775V + 0.775V rms balanced
Input impedances Balanced input 38 kOhm
Unbalanced input 68 kOhm
Damping factor > 125 at 1 kHz
Trigger In 5 - 12V AC or DC
Trigger Out 12V DC @ 100mA
Power consumption Maximum 2400W
Active (no signal) < 180W
Standby < 5W
Dimensions (H x W x D) 148 x 430 x 365mm
(5.8 x 16.9 x 14.4”)
Weight 19.1kg (42.1lbs)
Technical specifications
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Cambridge Audio Azur 840W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Cambridge Audio Azur 840W in the language / languages: English as an attachment in your email.

The manual is 2,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Cambridge Audio Azur 840W

Cambridge Audio Azur 840W User Manual - German - 12 pages

Cambridge Audio Azur 840W User Manual - Dutch - 12 pages

Cambridge Audio Azur 840W User Manual - Danish - 12 pages

Cambridge Audio Azur 840W User Manual - French - 12 pages

Cambridge Audio Azur 840W User Manual - Italian - 12 pages

Cambridge Audio Azur 840W User Manual - Spanish - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info