Electrolytic corrosion will occur when dissimilar metals
at are in contact wi each oer create a potential
difference between emselves. Sometimes separated
by a conductive substance known as an electrolyte, e
dissimilar metals will create a small voltage (potential
difference) at allows e ions of one material to pass
to e oer.
Just like a battery, ions will pass from e most positive
material to e more negative material.
Anying more an 0.3 volts can cause e most
positive material to degrade.
A swimming pool wi its associated equipment
can create is effect. The pool water being an ideal
electrolyte and components of e filtration circuit,
heating system, steps, lights etc providing e dissimilar
metals needed to complete e circuit.
Whilst ese small voltages are rarely a safety reat,
ey can create premature failure rough corrosion.
Not dissimilar to corrosion rough oxidation, electrolytic
corrosion can cause complete failure of a metallic
material in a very short period of time.
In order to prevent is type of corrosion all metallic
components in contact wi swimming pool water
should be bonded togeer using 10mm² bonding
cable. This includes non-electrical items such as metal
filters, pump strainer boxes, heat exchangers, steps
and handrails. It is highly recommended at bonding
be retrofitted to existing pools, which may not be
protected by is system.
All electrical work to be carried out in accordance wi
l.E.E.regulations, latest issue, or local codes of practice
as applicable. .
The machine should be installed in accordance wi
EMC2004/108/EC.
Always isolate e main ower supply before removing
machine covers.
The machine power supply must incorporate e
following. Fuses or motor type circuit breakers (aM
Fuse / MCB type C) to specified rating (see datasheet).
When using a fuse, H.R.C. fuses are recommended. An
isolator which disconnects all poles must be must fitted
wiin 2m and in line of sight of e heat pump. The
isolator must have a minimum of 3mm air gap when
turned off.
All units must be correctly eared/grounded and its
own separate type F RCD ear leakage trip installed
which protects e machine only.
The following limits of operation must not be exceeded.
Failure to provide e necessary voltages will invalidate
e warranty. This voltage must be available at e heat
pump whilst running. The voltage must not drop below
e above figures when starting e compressor.
Minimum Maximum
Voltage
Single phase machines 207V 253V
Cycle frequency (50Hz) 47.5Hz 52.5Hz
3�6 ELECTROLYTIC CORROSION IN SWIMMING
POOLS
3�7 ELECTRIC WIRING AND SUPPLY
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Calorex V-PAC inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Calorex V-PAC inverter in the language / languages: English as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info