752402
37
Zoom out
Zoom in
Previous page
1/44
Next page
37
1005494 ISSUE 5
MODEL UNITS IPT 12 ALY IPT16 ALY IPT22 ALY
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity kW 15.0 21.0 27.5
COP range 15.0-6.6 14.8-6.4 15.0-6.5
Average COP at 50% Speed 10.6 10.3 10.3
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity kW 10.5 14.5 18.0
COP range 7.7-4.6 7.1-4.6 7.5-4.6
Average COP at 50% Speed 6.4 6.3 6.3
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity kW 6.7 9.5 11.9
TECHNICAL SPECIFICATIONS
Operating air temperature °C -10°C to 43°C
Water heating setting range 18°C to 40°C
Water cooling setting range 12°C to 30°C
POWER SUPPLY 230V Single Phase 50Hz
Rated input power kW 0.27-2.28 0.41-3.15 0.48-3.91
Rated input current A 1.17-9.91 1.78-13.69 2.08-17.00
Maximum input current A 13.5 17 20
Rated RCD type F mA 30 30 30
Rated Fuse aM / MCB type C A 20 25 25
Sound pressure level at 10m dB(A) 20.8-24.5 20.4-33.7 23.0-34.4
Recommended water flow rate m3/h 5.0-7.0 8.0-10.0 10.0-12.0
Pressure drop m/kPa 0.49/4.8 0.61/6.0 0.77/7.5
Pool water connections Inches 1½” or 50mm Female
GENERAL DATA
Net dimensions (w x d x h) mm 954x359x648 954x429x755 1084x429x948
Packed dimensions (w x d x h) mm 1040x445x655 1040x445x655 1130x445x985
Net weight kg 52 68 90
HERMETIC SYSTEM
Refrigerant charge R32 kg 0.9 1.2 2.0
Minimum area requirement m2 6.9 12.3 34.0
NOTES: Heat pump performance parameters are subject to change wiout notice. Always refer to e nameplate.
Global warming potential (GWP) R32 - 675.
The data is subject to modification wiout prior warning.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Calorex i-Pac inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Calorex i-Pac inverter in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info