752402
18
Zoom out
Zoom in
Previous page
1/44
Next page
18 1005494 ISSUE 5
OWNER/INSTALLATION MANUAL
L N
Fuse/MCB
Eared Power
Supply 230V 50Hz
Supply
cord
Distribution box
L N
RCD/
Circuit
Breaker
P1 P2
Power
terminals
Pump
terminals
Cable clamp
Single phase
Terminals in Heat Pump Electrics enclosure
Isolator which
disconnects all poles
fitted wiin 2m and in line
of sight of e heat pump
Secure cables
using cable clamps
and feed rough
cable entry points in
machine
Isolator which
disconnects all poles
fitted wiin 2m and in line
of sight of e heat pump
L3
N
Fuses/MCB
Eared Power
Supply 400V 50Hz
L3 N P1 P2
Power
terminals
Pump
terminals
L2
L1
L2
L1
Three phase
Terminals in Heat Pump Electrics enclosure
Cable clamp
Supply
cord
RCD/
Circuit
Breaker
Distribution box
Secure cables
using cable
clamps and feed
rough cable
entry points in
machine
Remove ese
two screws
Li lower
panel away
1
Remove ese
four screws and
remove cover
Two cable
entry points
2
3�8 CONNECTING THE HEAT PUMP TO THE POWER
SUPPLY
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Calorex i-Pac inverter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Calorex i-Pac inverter in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info